ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

499

Found

Advisory data: live connection— last retrieved: 20 November 2026 at 21:19.

Filters

499 advisories found

SA26P001

​​PVI​ ​​Insertion of Sensitive Information into Logfile

B&R Industrial Automation GmbH — ​​PVI​

ABB PSIRTmiddel

Published

29 January 2026

Last update

14 May 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB became aware of vulnerability in the product versions listed as affected in the advisory. An update is now available that addresses and remediates the vulnerability. An attacker who successfully exploited this vulnerability could read sensitive information in the logging data of the PVI client application. Logging is deactivated by default in all PVI client versions.

Mitigation summary

The problem is corrected in the following product versions: - PVI 6.5.0 Please note that PVI is included in the Automation Studio installation package and shares the same version number as the corresponding Automation Studio release. B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.

Revision history (2)
  1. Initial publication — 29 January 2026

    Initial version.

  2. Update A — 14 May 2026

    Corrected vendor name from 'ABB' to 'B&R Industrial Automation GmbH' to ensure accurate product matching.

Official source: ABB PSIRT

SEVD-2025-014-07

FlexNet Publisher Vulnerability

Schneider Electric — EcoStruxure Control Expert

Schneider Electric CPCERThigh

Published

14 January 2025

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability disclosed on Revenera FlexNet Publisher component. Many vendors, including Schneider Electric, embed Revenera FlexNet Publisher in their offers. Failure to apply the remediation/mitigations provided below may risk a local privilege escalation, which could lead to the execution of a malicious DLL with elevated privilege.

Mitigation summary

Version 16.2 of EcoStruxure™ Control Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/ Reboot the computer after installation is completed.

Revision history (4)
  1. Initial publication — 14 January 2025

    Original Release

  2. Update A — 11 February 2025

    A remediation is available for the EcoStruxure™ Process Expert offer. The EcoStruxure™ Process Expert for AVEVA System Platform offer is added to the “Affected Product and Versions” section

  3. Update B — 8 July 2025

    Pro-face BLUE is added to the “Affected Product and Versions” section. Remediations are now available for EcoStruxure™Control Expert, EcoStruxure™ Operator Terminal Expert and Pro-face BLUE offers. Updated the link to the fix of EcoStruxure™ Control Expert Asset Link offer

  4. Update C — 14 October 2025

    A remediation is now available for Zelio Soft 2 and EcoStruxure™ OPC UA Server Expert offers

Official source: Schneider Electric CPCERT

SEVD-2025-042-03

EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform

Schneider Electric — EcoStruxure™ Process Expert

Schneider Electric CPCERThigh

Published

11 February 2025

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxure™ Process Expert, EcoStruxure™ Process Expert for AVEVA System Platform products are engineering tools that facilitates and automates the design, maintenance, commissioning, and operation of Control projects for Modicon controllers and the associated Supervision projects for SCADA software regrouped in a system.. Failure to apply the Fix/Mitigations provided below may risk a local privilege escalation, which could result in loss of confidentiality, integrity and availability of the engineering workstation.

Mitigation summary

Version v4.8.0.5715 of EcoStruxure™ Process Expert 2023 Software Package includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-processexpert/#software-and-firmware Uninstall Previous Version 2023 (v4.8.0.5115) before installing Version 2023 (v4.8.0.5715). Version string could be found on engineering server console.

Revision history (2)
  1. Initial publication — 11 February 2025

    Original Release

  2. Update A — 12 May 2026

    A remediation is available for EcoStruxure™ Process Expert for AVEVA System Platform

Official source: Schneider Electric CPCERT

SEVD-2025-042-02

Improper Input Validation Vulnerability in Uni-Telway Driver

Schneider Electric — EcoStruxure Control Expert

Schneider Electric CPCERTmiddel

Published

11 February 2025

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its [Uni-Telway driver](https://www.se.com/us/en/product-range/573-unitelway/#overview) which is part of [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview), [EcoStruxure™ Process Expert](https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert), [EcoStruxure™ Process Expert for AVEVA System Platform](https://www.se.com/ww/en/product-range/55570689-ecostruxure-process-expert-for-aveva-system-platform/#overview) and [OPC Factory Server](https://www.se.com/ww/en/product-range/547-opc-factory-server/) products. Failure to apply the mitigations provided below may risk denial of service of engineering workstation, which could result in interruption of engineering operation.

Mitigation summary

For customers requiring the use of Uni-Telway driver, Schneider Electric recommends using following mitigations to reduce the risk of exploit:• McAfee Application and Change Control software for application control. Refer to the Cybersecurity Application Note available https://www.se.com/ww/en/download/document/EIO0000004778/ • Follow workstation, network and site-hardening guidelines in the Schneider Electric [Recommended Cybersecurity Best Practices](https://www.se.com/ww/en/download/document/7EN52-0390/) document. For customers not requiring the use of Uni-Telway driver, Schneider Electric recommends uninstalling the driver. Version 16.2 of EcoStruxureTM Control Expert, version 2025 of EcoStruxureTM Process Expert, version 2025 of EcoStruxureTM Process Expert for AVEVA System Platform, and version 3.63SP3 of OPC Factory Server do not include Uni-Telway driver by default anymore. This vulnerability is only affecting customers who have installed Uni-Telway driver.

Revision history (4)
  1. Initial publication — 11 February 2025

    Original Release

  2. Update A — 8 July 2025

    Mitigations section updated for EcoStruxure™ Control Expert and OPC Factory Server.

  3. Update B — 13 January 2026

    Mitigations are now available for EcoStruxure™ Process Expert. EcoStruxure™ Process Expert found to be not affected by this vulnerability and advisory title has been modified

  4. Update C — 10 February 2026

    Removed comment “EcoStruxure™ Process Expert found to be not affected by this vulnerability.

Official source: Schneider Electric CPCERT

SEVD-2026-013-02

Incorrect Default Permissions Vulnerability on EcoStruxure™ Process Expert

Schneider Electric — EcoStruxure™ Process Expert

Schneider Electric CPCERThigh

Published

13 January 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its EcoStruxureTM Process and EcoStruxure™ Process Expert for AVEVA System Platform products. The EcoStruxureTM Process is a single automation system to engineer, operate, and maintain your entire infrastructure for a sustainable, productive and market-agile plant. The EcoStruxure™ Process Expert for AVEVA System Platform product enables users to achieve operational profitability from design engineering to meeting the demands of modern-day production. It provides an asset centric and object-oriented automation platform to deploy system-wide standards in a digital ecosystem. Failure to apply the Fix/Mitigations provided below may risk modification of the executable binaries, which could result in privilege escalation.

Mitigation summary

Version 2025 of EcoStruxure™ Process Expert includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/65406-ecostruxure-process-expert

Revision history (2)
  1. Initial publication — 13 January 2026

    Original Release

  2. Update A — 12 May 2026

    A remediation is available for EcoStruxure™ Process Expert for AVEVA System Platform

Official source: Schneider Electric CPCERT

SEVD-2026-132-04

Initialization of a Resource with an Insecure Default vulnerability on EcoStruxure Panel Server

Schneider Electric — EcoStruxure Panel Server

Schneider Electric CPCERThigh

Published

12 May 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of its vulnerability in its EcoStruxure Panel Server offer. The EcoStruxure Panel Server is a high performance, modular gateway with enhanced cybersecurity that provides easy and fast connections to multiple concurrent edge control or cloud applications. Failure to apply the remediations provided below may risk unauthorized authentication, which could lead to access to sensitive information.

Mitigation summary

Version 002.006.000 of EcoStruxure Panel Server includes a fix for this vulnerability and is available for download here: • https://www.se.com/ww/en/download/document/PAS800_Fir mware_Package/ • Reboot needed: Yes

Revision history (1)
  1. Initial publication — 12 May 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-132-03

Improper Limitation of a Pathname to a Restricted Directory vulnerability on Remote Terminal Unit and Controller Products

Schneider Electric — EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller

Schneider Electric CPCERThigh

Published

12 May 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

, Transmissie, Energieopwekking

Risk evaluation

Schneider Electric is aware of a vulnerability in its EasyLogic T150 (formerly known as Saitel DR) and Saitel DP Remote Terminal Unit & Controller products. The [EasyLogic T150 (formerly known as Saitel DR RTU)](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=62685#overview) is a field device, offering a solid and powerful modular platform for data acquisition, communication, automation and IED integration for distribution and transmission networks, generation sector and railway. The [Saitel DP RTU](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=61747) is a modular platform for medium voltage and high voltage public distribution and transmission substation control. Failure to apply the fix provided below may risk a path traversal–based attack in which an authenticated user could gain unauthorized file access.

Mitigation summary

Version 11.06.32 of EasyLogic T150 (formerly Saitel DR) Remote Terminal Unit & Controller includes a fix for this vulnerability and is available for download here: • Contact Schneider Electric’s Customer Care Center to download this firmware. • Reboot needed: Yes

Revision history (1)
  1. Initial publication — 12 May 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-104-03

Use of Hard-coded Credentials vulnerability on Easergy MiCOM Px40 Series

Schneider Electric — Easergy MiCOM

Schneider Electric CPCERTmiddel

Published

14 April 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Easergy MiCOM Px40 Series products. The [Easergy MiCOM Px40](https://www.se.com/ww/en/product-subcategory/4725-easergy-micom-px40-series/?filter=business-6-medium-voltage-distribution-and-grid-automation) is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. Failure to apply the mitigations provided below may risk unauthorized exposure of basic device identification through the SNMP protocol.

Mitigation summary

For customers who do not require SNMP Contact Schneider Electric's [Customer Care Center](https://www.se.com/ww/en/work/support/contacts.jsp) to upgrade the Firmware to a version without SNMP functionality. If customers choose not to apply the upgrade provided above, they should immediately apply the following mitigations to reduce the risk of exploit: * Use relays only in a protected network environment, * Use firewalls to protect and separate the control system network from other networks, * Use VPN (Virtual Private Networks) tunnels if remote access is required. For customers who require SNMP Please immediately apply the following mitigations to reduce the risk of exploit: * Use relays only in a protected network environment, * Use firewalls to protect and separate the control system network from other networks, * Use VPN (Virtual Private Networks) tunnels if remote access is required.

Revision history (2)
  1. Initial publication — 14 April 2026

    Original Release

  2. Update A — 12 May 2026

    Updated the risk associated with successful exploitation of this vulnerability and revised the remediation table to a mitigation table to emphasize that multiple mitigation options are available.

Official source: Schneider Electric CPCERT

SEVD-2026-132-01

Clear Text Storage of Sensitive Information vulnerability on EcoStruxure™ Machine Expert HVAC

Schneider Electric — Ecostruxure™ Machine Expert HVAC

Schneider Electric CPCERTmiddel

Published

12 May 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its EcostruxureTM Machine Expert HVAC product. The [EcostruxureTM Machine Expert HVAC](https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC/) product is a programming software for Modicon M171-M172 logic controllers. Failure to apply the remediation provided below may risk in revealing sensitive information, which could result in disclosing protected source code, leading to loss of confidentiality.

Mitigation summary

Version 1.10.0 of Ecostruxure™ Machine Expert HVAC includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/EcoStruxureME_HVAC_1_10_0/

Revision history (1)
  1. Initial publication — 12 May 2026

    Original Release

Official source: Schneider Electric CPCERT

Advisory2026-05_VDE-2026-042

CODESYS Modbus TCP Server - Improper resource management

CODESYS — CODESYS Modbus

CODESYS PSIRTmiddel

Published

12 May 2026

Last update

12 May 2026

Linked CVEs

Affected sectors

Risk evaluation

CODESYS Modbus is an add‑on for the CODESYS Development System that provides a fully integrated Modbus protocol stack along with diagnostic capabilities. A flaw in the CODESYS Modbus TCP Server protocol stack library results in a vulnerability. When a Modbus TCP server is configured, this vulnerable protocol stack is downloaded to and executed by CODESYS Control runtime systems. The vulnerability is caused by a resource management issue in the Modbus TCP server and is only exploitable if a race condition in the connection handling is successfully triggered. Over time, this may exhaust the configured maximum number of connections, potentially preventing new connections from being accepted. Existing connections remain unaffected and continue to operate normally. This issue affects only CODESYS projects that include a Modbus TCP server configuration.

Mitigation summary

Update the following product to version 4.6.0.0. * CODESYS Modbus To make the fix effective for existing CODESYS projects, you must additionally update the local Modbus TCP Server in the device tree to the latest version and perform a download of the CODESYS application to the PLC. The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.

Revision history (1)
  1. Initial publication — 12 May 2026

    Initial revision.

Official source: CODESYS PSIRT

VDE-2026-005

ifm: Multiple Vulnerabilities in CR3171

ifm — CR3171

ifm PSIRThigh

Published

6 May 2026

Last update

6 May 2026

Affected sectors

Risk evaluation

The Firmware installed on the CR3171 is impacted by various CODESYS vulnerabilities.

Mitigation summary

will be fixed in Firmware Version 3.3

Revision history (1)
  1. Initial publication — 6 May 2026

    initial release

Official source: ifm PSIRT

PPSA-2026-002

Pilz: Vulnerability affecting PASvisu Runtime

Pilz — PMIv7xxe

Pilz PSIRThigh

Published

23 April 2026

Last update

23 April 2026

Linked CVEs

Affected sectors

Risk evaluation

The PASvisu Runtime is affected by a vulnerability in a third-party component which can be exploited by malicious web requests.

Mitigation summary

Limit network access to PASvisu server by using a firewall, a host-based firewall or similar measures.

Revision history (1)
  1. Initial publication — 23 April 2026

    Initial Version

Official source: Pilz PSIRT

VDE-2026-023

Phoenix Contact: Several products are affected by vulnerabilities found in OpenSSL

Phoenix Contact — CHARX SEC

Phoenix Contact PSIRTcritical

Published

22 April 2026

Last update

22 April 2026

Affected sectors

Risk evaluation

Attacks are possible when installing key files and digitally signed objects. These attacks can only be carried out if these files are uploaded and installed by a logged-in user with high privileges.

Mitigation summary

Phoenix Contact strongly recommends to upload firmware only from trusted source and to thorougly check the SHA256 checksum of the firmware image to be uploaded.

Revision history (1)
  1. Initial publication — 22 April 2026

    Initial release.

Official source: Phoenix Contact PSIRT

VDE-2026-015

Helmholz: Use of a Broken or Risky Cryptographic Algorithm

Helmholz — WALL IE Standard 4-Port

Helmholz PSIRThigh

Published

21 April 2026

Last update

21 April 2026

Linked CVEs

Affected sectors

Risk evaluation

Vulnerabilities in WALL IE devices with firmware <= V1.10.210 that allow an attacker to gain control over the device.

Mitigation summary

Update to latest firmware 1.10.232

Revision history (2)
  1. Initial publication — 21 April 2026

    Initial revision.

  2. Update A — 21 April 2026

    fixed release date

Official source: Helmholz PSIRT

VDE-2026-032

Endress+Hauser: sudo vulnerability affects Endress+Hauser MCS200HW

Endress+Hauser — Extractive Analyzer

Endress+Hauser PSIRThigh

Published

21 April 2026

Last update

21 April 2026

Linked CVEs

Affected sectors

Risk evaluation

The display unit of the Endress+Hauser MCS200HW is affected by a sudo chroot vulnerability.

Mitigation summary

The display unit's firmware versions below 4.3.4 are affected. To address the vulnerability, customers are strongly recommended to update the display unit of their devices to firmware version 4.3.4. Endress+Hauser will include this firmware version in the MCS200HW products starting with version 1.11.5.6R. Alternatively, customers can contact Endress+Hauser directly to obtain the updated display firmware, or download the original firmware - including update instructions - from the Phoenix Contact website referenced below.

Revision history (1)
  1. Initial publication — 21 April 2026

    Initial version

Official source: Endress+Hauser PSIRT

SEVD-2024-163-01

Modicon M340, Modbus/TCP Ethernet Modicon M340 module, and Modbus/TCP Ethernet Modicon M340 FactoryCast module

Schneider Electric — Modicon M340

Schneider Electric CPCERTmiddel

Published

11 June 2024

Last update

14 April 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Modicon M340 and BMXNOE0100 and BMXNOE0110 products. The Modicon M340 is a programmable automation controller; BMXNOE0100 and BMXNOE0110 are network modules used with Modicon M340. Failure to apply the mitigations provided below may prevent user to update the device firmware and prevent proper behavior of the webserver. The BMXNOE and Modicon M340 operations are not impacted by this vulnerability. August Update: Remediations are available for BMXNOE0100 (Modbus/TCP Ethernet Modicon M340 module) and BMXNOE0110 (Modbus/TCP Ethernet Modicon M340 FactoryCast module)

Mitigation summary

Version SV3.60 of BMXNOE0100 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card

Revision history (3)
  1. Initial publication — 11 June 2024

    Original Release

  2. Update A — 12 August 2025

    Remediations are available for BMXNOE0100 (Modbus/TCP Ethernet Modicon M340 module) and BMXNOE0110 (Modbus/TCP Ethernet Modicon M340 FactoryCast module)

  3. Update B — 14 April 2026

    Remediation is available for Modicon M340

Official source: Schneider Electric CPCERT

SEVD-2025-014-05

Web Server on Modicon M340, Modbus/TCP Ethernet Modicon M340 module, Modbus/TCP Ethernet Modicon M340 FactoryCast module and Ethernet / Serial RTU communication modules

Schneider Electric — Modicon M340 processors

Schneider Electric CPCERThigh

Published

14 January 2025

Last update

14 April 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Web Server on Modicon M340 and BMXNOE0100/0110, BMXNOR0200H communication modules products. The Modicon M340 is a programmable automation controller; BMXNOE0100 and BMXNOE0110 are network communication modules used with Modicon M340. BMXNOR0200H is a communication module that enables M580 and M340 platforms to use RTU protocol exchange with RTU stations. Failure to apply the remediation/mitigations provided below may risk information disclosure on web pages, modification of web pages and denial of serviceClick or tap here to enter text., which could result in the unavailability of the controllers or modules. August Update: Remediations are available for BMXNOE0100 (Modbus/TCP Ethernet Modicon M340 module) and BMXNOE0110 (Modbus/TCP Ethernet Modicon M340 FactoryCast module)

Mitigation summary

Version SV1.70IR26 of BMXNOR0200H includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOR0200H/ethernet-serial-rtu-module-2-x-rj45/

Revision history (3)
  1. Initial publication — 14 January 2025

    Original Release

  2. Update A — 12 August 2025

    Remediations are available for BMXNOE0100 (Modbus/TCP Ethernet Modicon M340 module) and BMXNOE0110 (Modbus/TCP Ethernet Modicon M340 FactoryCast module)

  3. Update B — 14 April 2026

    Remediation is available for Modicon M340

Official source: Schneider Electric CPCERT

SEVD-2026-104-02

Third-Party vulnerability on Modicon Networking Managed Switches

Schneider Electric — Connexium Managed Switches

Schneider Electric CPCERTcritical

Published

14 April 2026

Last update

14 April 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a RADIUS protocol vulnerability affecting its Modicon Network Managed Switch product. The Modicon Network Managed Switch product provides connectivity for multiple Ethernet devices, network management, enhanced cyber security and more advanced switching features. Failure to apply the mitigation provided below may risk forgery attacks in RADIUS Protocol, which could result in modification of any valid Response (Access-Accept, Access-Reject, or Access-Challenge) to any other response which could result in the possibility of denial of service and loss of confidentiality, integrity of the devices connected to the switch.

Mitigation summary

The default RADIUS configuration is not vulnerable. However, if the RADIUS Server Message Authenticator option is disabled, the product becomes vulnerable.We advise keeping this parameter in its default (enabled) state.This parameter can be configured via CLI and SNMP:TCSESM* CLI: radius server msgauthMIB: hmAgentRadiusServerMsgAuth

Revision history (1)
  1. Initial publication — 14 April 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-104-01

Multiple Vulnerabilities on PowerChute™ Serial Shutdown

Schneider Electric — Microsoft Windows

Schneider Electric CPCERTmiddel

Published

14 April 2026

Last update

14 April 2026

Affected sectors

Risk evaluation

Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The [PowerChute Serial Shutdown](https://www.se.com/ww/en/product-range/137943580-powerchute-serial-shutdown/#products) product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktop, servers and workstations. Failure to apply the remediation provided below may risk improper input validation which could result in disruption of operations and access to system data.

Mitigation summary

Version v1.5 of PowerChute™ Serial Shutdown includes a fix for this vulnerability and is available for download here: • Windows: https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Specific instructions and hardening guidelines for these mitigations can be found in the [Security Handbook](https://download.schneider-electric.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN).

Revision history (1)
  1. Initial publication — 14 April 2026

    Original Release

Official source: Schneider Electric CPCERT

VDE-2024-008

Wago: Vulnerability in WBM through Open VPN

WAGO — CC100

WAGO PSIRThigh

Published

8 April 2026

Last update

8 April 2026

Linked CVEs

Affected sectors

Risk evaluation

A security vulnerability has been identified in the Web-Based Management (WBM) function when OpenVPN is enabled.

Mitigation summary

The user is able to drop privileges of OpenVPN. How to do this is described in the manual "WAGO I/O System 750/753" at section 7.1.1.5.1.

Revision history (1)
  1. Initial publication — 8 April 2026

    Initial Release.

Official source: WAGO PSIRT

VDE-2026-013

Helmholz: Use of a Broken or Risky Cryptographic Algorithm

Helmholz — FLEXtra FLAT PROFINET-Switch

Helmholz PSIRThigh

Published

7 April 2026

Last update

7 April 2026

Linked CVEs

Affected sectors

Risk evaluation

Vulnerabilities in PROFINET-Switch devices with firmware <= V1.12.010 that allow an attacker to gain control over the device.

Mitigation summary

Update to latest firmware 1.12.100

Revision history (1)
  1. Initial publication — 7 April 2026

    Initial revision.

Official source: Helmholz PSIRT

VDE-2026-030

MB connect line: Multiple Vulnerabilities in mbCONNECT24/mymbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRTcritical

Published

2 April 2026

Last update

2 April 2026

Affected sectors

Risk evaluation

Multiple vulnerabilities have been discovered in MB connect line mbCONNECT24/mymbCONNECT24 that could allow RCE, SQLi or information leakage.

Mitigation summary

Update the mbCONNECT24/mymbCONNECT24 instance to version 2.19.4.

Revision history (1)
  1. Initial publication — 2 April 2026

    Initial revision.

Official source: MB connect line PSIRT

VDE-2025-107

Endress+Hauser: Multiple products affected by Qualcomm vulnerabilities

Endress+Hauser — Liquiline Edge Module EMR

Endress+Hauser PSIRTcritical

Risk evaluation

Multiple vulnerabilities in a Qualcomm component have been reported in a closed-source report. This component is an integral part of the radio chip found in several Endress+Hauser products.

Mitigation summary

If a firmware update is no longer possible, it is recommended to replace the device.

Revision history (2)
  1. Initial publication — 5 December 2025

    Initial version

  2. Update A — 2 April 2026

    Updated CPEs

Official source: Endress+Hauser PSIRT

VDE-2026-003

Endress+Hauser: Multiple products prone to multiple vulnerabilities in e!Runtime and CODESYS V3 Runtime

Endress+Hauser — CC 100

Endress+Hauser PSIRThigh

Risk evaluation

Multiple Endress+Hauser devices are prone to vulnerabilities found in e!Runtime and the CODESYS V3 framework.

Mitigation summary

The CDC 90 device is not designed for network connectivity by default. Since it is not connected to a network, the vulnerabilities cannot be exploited. However, if the customer chooses to connect the device to a network, the default firewall settings should be maintained, as this will mitigate the security vulnerabilities. For the CC 100 and PFC 200 devices, ensure that the default firewall settings remain intact and that both PLC Runtime and PLC WebVisu are disabled. This configuration effectively mitigates the identified security vulnerabilities.

Revision history (2)
  1. Initial publication — 31 March 2026

    Initial version

  2. Update A — 1 April 2026

    Edited a typo in product tree.

Official source: Endress+Hauser PSIRT

SEVD-2026-069-02

Improper Neutralization vulnerability in Multiple Products

Schneider Electric — Modicon Controllers

Schneider Electric CPCERTmiddel

Published

10 March 2026

Last update

31 March 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Modicon Controllers M241 / M251, M258, and LMC058 products. The [Modicon Controllers M241 / M251 / M258](https://www.se.com/ww/en/product-category/3900-plc-pac-and-dedicated-controllers/) and [Modicon LMC058](https://www.se.com/ww/en/product-range/7744-modicon-lmc058/) are Programmable Logic Controllers for performance-demanding applications. Failure to apply the remediation or mitigations provided below may risk a Cross-site Scripting or an open redirect attack which could result in an account takeover scenario or the execution of code in the user browser.

Mitigation summary

Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/ Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/

Revision history (2)
  1. Initial publication — 10 March 2026

    Original Release

  2. Update A — 31 March 2026

    Updated the acknowledgement section.

Official source: Schneider Electric CPCERT