SEVD-2026-069-01
Improper Resource Shutdown or Release vulnerability in Multiple Products
Risk evaluation
Schneider Electric is aware of a vulnerability in its Modicon Controllers M241 / M251, and M262 products. The Modicon Controllers M241 / M251 / M262 are Programmable Logic Controllers for performancedemanding applications. Failure to apply the remediation provided below may risk Denial of Service attack which could result in loss of availability of the controller
Mitigation summary
Modicon Controller M241 Firmware version 5.4.13.12 delivered with EcoStruxure™ Machine Expert v2.5.0.1 includes a fix for this vulnerability and can be installed through Schneider Electric Software Installer available here: https://www.se.com/ww/en/download/document/ESEMACS10_INSTALLER/ On the engineering workstation install v2.5.0.1 of EcoStruxure™ Machine Expert. For help refer to Schneider Electric Software Installer User Guide available here: https://www.se.com/ww/en/download/document/EIO0000005500/ Update Modicon Controller M241 to the latest Firmware and perform reboot. For instructions refer to Modicon M241 Logic Controller, Programming Guide: https://www.se.com/ww/en/download/document/EIO0000003059/
Revision history (2)
Initial publication — 10 March 2026
Original Release
Update A — 31 March 2026
Updated the acknowledgement section.
VDE-2026-010
WAGO: Multiple Vulnerabilities in WAGO Solution Builder and WAGO Device Sphere
Published
30 March 2026
Last update
30 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been identified in WAGO Solution Builder and WAGO Device Sphere that affect components responsible for authentication and system communication.
Mitigation summary
Update to WAGO Device Sphere version 1.2.2. and WAGO Solution Builder version 2.4.2
Revision history (1)
Initial publication — 30 March 2026
Initial release.
Published
30 March 2026
Last update
30 March 2026
Linked CVEs
Affected sectors
Risk evaluation
The VC Hub incorporates the Magick.NET‑Q16‑AnyCPU component, derived from ImageMagick, to process user‑uploaded images and generate thumbnails within the projects image library. Only authenticated users with the Design Project Permission can upload images.
Mitigation summary
Update the WAGO Visualization And Control Hub to version 5.0.1.
Revision history (1)
Initial publication — 30 March 2026
Initial release.
VDE-2026-024
MB connect line: Multiple Vulnerabilities in mbCONNECT24/mymbCONNECT24
Published
23 March 2026
Last update
23 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been discovered in MB connect line mbCONNECT24/mymbCONNECT24 that could allow unauthenticated RCE or SQLi.
Mitigation summary
Update the mbCONNECT24/mymbCONNECT24 instance to version 2.19.4.
Revision history (1)
Initial publication — 23 March 2026
Initial revision.
Published
23 March 2026
Last update
23 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been discovered in Helmholz myREX24V2 / myREX24V2.virtual that could allow unauthenticated RCE or SQLi.
Mitigation summary
Update the myREX24V2 / myREX24V2.virtual instance to version 2.19.4.
Revision history (1)
Initial publication — 23 March 2026
Initial revision.
Risk evaluation
A vulnerability has been found affecting the Managed Switches of WAGO. An unauthenticated attacker can fully compromise the device via an undocumented function.
Mitigation summary
Please update your devices to the specified fixed firmware version. | Product | Fixed Version | |-------------------------------------------|---------------| | Lean Managed Switch 852-1812 | V1.2.1.S1 | | Lean Managed Switch 852-1813 | V1.2.1.S1 | | Lean Managed Switch 852-1813/000-001| V1.2.3.S1 | | Lean Managed Switch 852-1816 | V1.2.1.S1 | | Industrial Managed Switch 852-303 | V1.2.8.S1 | | Industrial Managed Switch 852-1305 | V1.2.0.S1 | | Industrial Managed Switch 852-1305/000-001| V1.2.0.S1 | | Industrial Managed Switch 852-1505/000-001| V1.2.0.S1 | | Industrial Managed Switch 852-1505 | V1.1.9.S1 | | Industrial Managed Switch 852-602 | V1.0.6.S1 | | Industrial Managed Switch 852-603 | V1.0.6.S1 | | Industrial Managed Switch 852-1605 | V1.2.5.S1 | | Lean Managed Switch 852-1812/010-000| V1.2.1.S1 | | Lean Managed Switch 852-1813/010-000| V1.2.1.S1 | | Lean Managed Switch 852-1813/010-001| V1.2.1.S1 | | Lean Managed Switch 852-1816/010-000| V1.2.1.S1 |
Revision history (1)
Initial publication — 23 March 2026
Release version.
VDE-2025-104
Phoenix Contact: Multiple Vulnerabilities in FL SWITCH 2xxx, FL SWITCH TSN 23xx and FL SWITCH 59xx Firmware
Published
18 March 2026
Last update
18 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been identified in the FL SWITCH 2xxx, FL SWITCH TSN 23xx and FL SWITCH 59xx firmware prior to version 3.53. One of these (CVE-2026-22317) enables an attacker to execute system commands as root user on the device. Five other vulnerabilities (CVE-2026-22316, CVE-2026-22318, CVE-2026-22319, CVE-2026-22320 and CVE-2026-22321) are related to Denial of Service (DoS) attacks, which partly limit the device's functionality. Another vulnerability (CVE-2026-22322) relates to reflected cross-site scripting in the web-based management of the device. And one vulnerability (CVE-2026-22323) relates to Cross‑Site Request Forgery in the web-based management of the device. All vulnerabilities have been resolved in firmware version 3.53.
Mitigation summary
Phoenix Contact strongly recommends to upgrade to firmware 3.53 which addresses this vulnerability and is available for download for all affected devices.
Revision history (1)
Initial publication — 18 March 2026
Initial release.
SEVD-2026-069-03
Deserialization of Untrusted Data vulnerability on EcoStruxure™ Foxboro DCS
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxure™ Foxboro DCS Control Software on Foxboro DCS workstations and servers. Control Core Services and all runtime software, like FCPs, FDCs, and FBMs, are not affected. The [EcoStruxure™ Foxboro DCS](https://www.se.com/ww/en/product-range/63680-ecostruxure-foxboro-dcs/) product is an innovative family of fault-tolerant, highly available control components, which consolidates critical information and elevates staff capabilities to ensure flawless, continuous plant operation. Failure to apply the remediation provided below may risk deserialization of untrusted data, which could result in loss of confidentiality, integrity and potential remote code execution on the compromised workstation.
Mitigation summary
Version CS 8.1 of EcoStruxure™ Foxboro DCS includes a fix for this vulnerability and is available through https://buyautomation.se.com/ CS 8.1 requires FX-V3 licenses, standard upgrade procedures apply. A reboot is required for workstations and servers. Depending on the existing system version, online upgrade without production interruption might be possible. We recommend you work with your local Field Service Representative or Technical Service Consultant for further information.
Revision history (2)
Initial publication — 10 March 2026
Original Release
Update A — 13 March 2026
Updated remediation and mitigations section.
Advisory2026-01_VDE-2026-012
CODESYS Installer - Possible Privilege Escalation
Risk evaluation
The CODESYS Installer is affected by a privilege escalation vulnerability. Due to a race condition, a local attacker with limited privileges can replace the verified downloaded setup before execution. Because the update process runs with administrator privileges, a malicious application can be executed with elevated rights. The attack requires the legitimate user to confirm the self‑update prompt for the CODESYS Installer itself or to initiate an installation of a CODESYS Development System. The update process for CODESYS Add-Ons is not affected by this issue.
Mitigation summary
Update the following product to version 2.6.1.0. * CODESYS Installer The CODESYS Installer as well as the CODESYS Development System can be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.
Revision history (1)
Initial publication — 10 March 2026
Initial revision.
SEVD-2026-069-06
Deserialization of Untrusted Data vulnerability on Multiple Products
Schneider Electric — EcoStruxure™ Power Monitoring Expert (PME) 2022
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxure™ Power Monitoring Expert (PME) and EcoStruxure™ Power Operation (EPO) products. EcoStruxure™ Power Monitoring Expert (PME) is an on-premises software used to help power critical and energy-intensive facilities maximize uptime and operational efficiency. EcoStruxure™ Power Operation (EPO) are on-premises software offers that provides a single platform to monitor and control medium and lower power systems.Failure to apply the fix provided below may risk local arbitrary code execution, which could result in the local system being compromised, a disruption of operations, and/or unauthorized administrative control of the system.
Mitigation summary
Hotfix_279338_Release_2024R2 is available for EcoStruxure™ Power Monitoring Expert (PME) that includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to download this hotfix. No reboot required.
Revision history (1)
Initial publication — 10 March 2026
Original Release
SEVD-2026-013-04
Multiple Vulnerabilities on EcoStruxure Power Build Rapsody
Schneider Electric — EcoStruxure Power Build Rapsody software
Published
13 January 2026
Last update
10 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Schneider Electric is aware of a vulnerability in its EcoStruxure Power Build Rapsody software. The [EcoStruxure Power Build Rapsody](https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309) is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components. Failure to apply the mitigations/remediations provided below may risk memory corruption, heap-based buffer overflow, stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code.
Mitigation summary
Versions FR V2.8.1.0401, INT V2.8.6.200, and ES V2.8.5.0301 of EcoStruxure™ Power Build Rapsody includes a fix for the CVE-2025-13844 vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309 Please restart the service after installing the new version.
Revision history (2)
Initial publication — 13 January 2026
Original Release
Update A — 10 March 2026
Removed the link to the fix for Rapsody Belgium version, which was privately communicated to impacted users
SEVD-2026-013-01
Multiple Third-Party Vulnerabilities on ProLeiT Plant iT/Brewmaxx
Published
13 January 2026
Last update
10 March 2026
Affected sectors
Risk evaluation
Schneider Electric is aware of multiple vulnerabilities in Redis open-source database, affecting its Plant iT product. The [Plant iT/Brewmaxx](https://www.proleit.com/plant-it/) product is an object-oriented and PLC-based process control system with integrated Manufacturing Execution System functionality. The integrated and modular software platform consists of basic systems, modules and add-ons that can be flexibly combined. Failure to apply the remediations provided below may risk privilege escalation, which could result in remote code execution.
Mitigation summary
Patch ProLeiT-2025-001 includes a fix to reduce the risk of exploit: • Install the patch to disable the eval commands in Redis on: o Application Server o VisuHub o Engineering Workstations o Workstation with emergency mode functionality • The patch ProLeiT-2025-001 is available via ProLeiT Support: https://www.proleit.com/support/ • Force usage of secure Redis configuration templates in system settings as documented in the patch manual. • Restart all patched Servers and Workstations
Revision history (2)
Initial publication — 13 January 2026
Original Release
Update A — 10 March 2026
Updated the CWE description of CVE-2025-46819
VDE-2025-096
Weidmueller: Multiple vulnerabilities in Energy Meter 750-24 and Energy Meter 750-230
Published
10 March 2026
Last update
10 March 2026
Affected sectors
Risk evaluation
An unauthenticated remote attacker can exploit several vulnerabilities in Weidmueller devices Energy Meter 750-24 and Energy Meter 750-230 to ultimately gain full system access and remote code execution.
Mitigation summary
Update to version 3.14
Revision history (1)
Initial publication — 10 March 2026
Initial version
Published
10 March 2026
Last update
10 March 2026
Affected sectors
Risk evaluation
An unauthenticated remote attacker can exploit several vulnerabilities in Janitza UMG 96RM-E devices to ultimately gain full system access and remote code execution.
Mitigation summary
It is strongly advised to update to the newest version. The vulnerabilities are fixed in version 3.14.
Revision history (1)
Initial publication — 10 March 2026
Initial Revision
VDE-2024-068
MB connect line: Multiple Vulnerabilities in MB connect line Products
Published
15 October 2024
Last update
6 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been discovered in MB connect line products that could allow RCE or unauthorized file access. CVE-2024-45272 affects the mbCONNECT24 and mymbCONNECT24 products. CVE-2024-45273 affects the mbNET/mbNET.rokey, mbCONNECT24, mymbCONNECT24, mbNET HW1, and mbSPIDER products. CVE-2024-45275 affects only the mbNET HW1 product.
Mitigation summary
**Note**: mbNET HW1 and mbSPIDER are EOL and will not receive any further updates.
Revision history (4)
Initial publication — 15 October 2024
Initial revision.
Update A — 6 November 2024
Fix: correct certvde domain, added self-reference
Update B — 14 May 2025
Fix: version space
Update C — 6 March 2026
Added CVE-2024-45275
Published
15 October 2024
Last update
6 March 2026
Linked CVEs
Affected sectors
Risk evaluation
Multiple vulnerabilities have been discovered in Helmholz products that could allow RCE or unauthorized file access. CVE-2024-45272 affects the myREX24V2 and myREX24V2.virtual products. CVE-2024-45273 affects the REX 200/REX 250, myREX24V2, myREX24V2.virtual products. CVE-2024-45275 affects only the REX 200 / REX 250 products.
Mitigation summary
**Note**: REX 300 is EOL and will not receive any further updates.
Revision history (4)
Initial publication — 15 October 2024
Initial revision.
Update A — 6 November 2024
Fix: correct certvde domain, added self-reference
Update B — 14 May 2025
Fix: version space
Update C — 6 March 2026
Added CVE-2024-45275
VDE-2026-002
Endress+Hauser: buffer overflow in glibc ld.so leading to privilege escalation
Risk evaluation
A vulnerability has been identified in WAGO devices utilized in Endress+Hauser IoT solutions. WAGO has provided fixes for these vulnerabilities, which have been integrated into the solutions by Endress+Hauser.
Mitigation summary
Local access is required to exploit this vulnerability. To mitigate the risk, ensure that only authorized personnel have physical access to the device.
Revision history (1)
Initial publication — 2 March 2026
Initial version
FSA-202601
Several CODESYS vulnerabilities in Festo Automation Suite
Published
26 February 2026
Last update
26 February 2026
Linked CVEs
Affected sectors
Risk evaluation
Starting with Festo Automation Suite (FAS) version 2.8.0.138, the suite is delivered only with a connector to Codesys, rather than including Codesys directly. Prior to this version, Codesys was bundled within the FAS installation. From version 2.8.0.138 onwards, customers are required to download and install Codesys independently. This change impacts the handling of security vulnerabilities (CVEs) related to Codesys. Any Codesys-related security issues must now be addressed by the customer through their separate Codesys installation. The FAS itself includes only the connector component, which is maintained and updated within the suite. Please ensure that Codesys is kept up to date independently to mitigate any potential security risks associated with the Codesys software.
Mitigation summary
Starting from Festo Automation Suite version 2.8.0.138, Codesys is no longer bundled with the suite and must be downloaded and installed separately by the customer. To mitigate this vulnerability customers are advised to: Download the latest, patched version of Codesys directly from the official Codesys website. Follow the installation and update instructions provided by Codesys to ensure all security fixes are applied. Regularly monitor Codesys security advisories and apply updates promptly. Maintain the Festo Automation Suite connector up to date by installing FAS updates as released by Festo.
Revision history (1)
Initial publication — 26 February 2026
Initial version
VDE-2025-109
Phoenix Contact: Unbounded growth of the session cache in TCP encapsulation service in FL MGUARD 2xxx and 4xxx firmware
Risk evaluation
The OpenSSL library used in the affected products is vulnerable to an unbounded growth of the session cache in the TLSv1.3 implementation.
Mitigation summary
It is recommended to disable TCP encapsulation on affected mGuard devices and use Pathfinder instead.
Revision history (2)
Initial publication — 10 February 2026
Initial release.
Update A — 23 February 2026
Updated category type in product tree.
VDE-2026-007
TRUMPF: Multiple products affected by Wibu CodeMeter vulnerability
Published
23 February 2026
Last update
23 February 2026
Linked CVEs
Affected sectors
Control centres
Risk evaluation
The TRUMPF product versions listed below include a Wibu CodeMeter component that is vulnerable to a privilege escalation vulnerability through the CodeMeter installer on Windows.
Mitigation summary
New versions are available for the affected products. These include an updated WiBu CodeMeter (bundled with TRUMPF License Expert). If your installation is affected, the easiest fix is to install the latest TRUMPF License Expert from https://www.trumpf.com/en_INT/products/software/software-licensing/. | Fixed Product | Version | | --------------------- | -------- | | TruTops Boost | 21.00.00 | | TecZone Bend | 25.11.1 | | Oseon | 8.00.00 | | Programming Tube | 6.9 | | TruTops Cell | 2.77.0 | | TruTops Weld | 11.0 | | TRUMPF License Expert | 2.3.2 |
Revision history (1)
Initial publication — 23 February 2026
Initial version
VDE-2025-068
Endress+Hauser: Proline 10 Maintenance credentials may be exposed under certain conditions
Risk evaluation
A privilege escalation vulnerability has been identified in Endress+Hauser's Proline 10 devices. This flaw allows an authenticated user with Operator-level access to elevate their privileges and gain Maintenance-level access, potentially enabling unauthorized configuration changes. Endress+Hauser has released a security update addressing this issue.
Mitigation summary
If an immediate firmware update is not feasible, it is recommended to disable the device's Bluetooth communication when not actively in use. This significantly reduces the risk of unauthorized access by eliminating the key vector through which the vulnerability could be exploited.
Revision history (2)
Initial publication — 2 September 2025
Initial version
Update A — 20 February 2026
fixed typo in alias
Risk evaluation
A vulnerability has been disclosed in PLC ifm AC4xxS that allows an attacker to trigger the safety state with the help of a specially crafted html request. This leads to a loss of availability.
Mitigation summary
When using automation components, make sure that no unauthorized access can take place. In addition, measures should be taken to ensure that the components do not have direct access to Internet resources and that they cannot be accessed from insecure networks. Use available security measures such as authentication and authorization groups. PLC with firmware V6.1.8 http interface can be disabled.
Revision history (3)
Initial publication — 30 June 2025
Initial release.
Update A — 16 February 2026
Updated content and product names.
Update B — 18 February 2026
Fixed Typo.
Risk evaluation
A vulnerability has been identified in the CODESYS Control runtime system, which includes an abstraction layer designed to ensure compatibility across different operating systems. This layer is used both by affected CODESYS products and by applications running on the PLC. The platform-specific adaptation of this abstraction layer for Linux and QNX contains a flaw in the SysSocket implementation. Due to incorrect internal handling and depending on how the caller interacts with the affected function, the issue can lead to an out-of-bounds read. An unauthenticated attacker may be able to exploit this vulnerability via socket-based communication, potentially causing a crash of the corresponding communication task. Additionally, also clients such as the PLCHandler running on Linux or QNX may be affected if they connect to a malicious server that triggers the flaw. Successful exploitation requires the attacker to win a race condition, which increases the complexity of the attack. Note: All platforms other than Linux and QNX are not affected.
Mitigation summary
As the flaw resides in the SysSocketSelect() implementation, which has been switched to a poll()-based approach by default since version 3.5.21.0, the following setting can be added to the configuration file of the affected product (e.g., CODESYSControl.cfg) to revert to the select()-based implementation: [SysSocket] LinuxSelectPoll=1 Note: On Linux select() is limited to less than 1024 file descriptors.
Revision history (2)
Initial publication — 1 December 2025
Initial revision.
Update A — 12 February 2026
Updated remediation category - fixed SL runtimes are now available.
Advisory2025-10_VDE-2025-100
CODESYS Control - Invalid type usage in visualization
Risk evaluation
A vulnerability in the CODESYS Control runtime system's CmpVisuServer component allows attackers to cause a denial-of-service (DoS) by sending special request to the CODESYS Web- or remote Target Visu. The issue is triggered by an internal read access using a pointer of wrong type. Only CODESYS Control runtime systems and PLCs based on the CODESYS Runtime Toolkit that include the CmpVisuServer component are impacted. In the case of CODESYS Web Visu, the vulnerability can only be exploited if the web server is running. When the web server starts depends on the startup configuration: By default, it is only running if the PLC executes application code that includes a visualization.
Mitigation summary
Update the following products to version 3.5.21.40. * CODESYS Control RTE (SL) * CODESYS Control RTE (for Beckhoff CX) SL * CODESYS Control Win (SL) * CODESYS HMI (SL) * CODESYS Remote Target Visu * CODESYS Runtime Toolkit The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.
Revision history (2)
Initial publication — 1 December 2025
Initial revision.
Update A — 12 February 2026
Updated remediation category - fixed SL runtimes are now available.
Risk evaluation
An optional package of the TwinCAT 3 XAR installs the TwinCAT 3 HMI Server on a device. It provides a server configuration page which can be accessed by administrative users only. When such an administrator accesses the server configuration page it is possible to upload arbitrary content into the CUSTOM_CSS field which is then persisted on the device and later returned and rendered with each login and error page. Please note that administrators have the access rights to modify any content on the HMI server, for example, via the server configuration page. Therefore, administrators would have to act maliciously to exploit this vulnerability.
Mitigation summary
Please update to a recent version of the affected components.
Revision history (2)
Initial publication — 10 December 2025
Initial revision
Update A — 12 February 2026
A typo was corrected in the CVE description.