Skip to content
IACS RadarIndustrial Cyber Exposure & Intelligence

CISA + vendors

ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

499

Found

Advisory data: live connection— last retrieved: 20 November 2026 at 19:46.

Filters

499 advisories found

sca-2026-0010

AppEngine vulnerability affects SICK ICR890-4 and SICK InspectorP6xx devices

SICK — Inspector

SICK PSIRTcritical

Published

28 July 2026

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

Multiple internal virtual filesystem paths are unintentionally accessible remotely in the SICK ICR890-4 and SICK InspectorP6xx devices. If exploited, this vulnerability could potentially allow an unauthenticated attacker to compromise the availability, integrity, and confidentiality of the devices.

Mitigation summary

Users are recommended to upgrade to version 5.4.0.

Revision history (3)
  1. Initial publication — 28 July 2026

    Initial version

  2. Update A — 24 August 2026

    Added ICR to the Products

  3. Update B — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2026-0012

Vulnerability Affecting Sentio Creator Extension 'Device Manager'

SICK — Engineering Tools

SICK PSIRThigh

Published

11 September 2026

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

The Device Manager extension shipped with Sentio Creator is affected by CVE-2026-80469. Affected versions are pre-installed in Sentio Creator releases up to and including version 2026.2. As the Device Manager extension can be updated independently of Sentio Creator, SICK recommends applying the defined remediations for this vulnerability.

Mitigation summary

Users are strongly recommended to upgrade the Device Manager extension for Sentio Creator to version 1.4.1.

Revision history (2)
  1. Initial publication — 11 September 2026

    Initial version

  2. Update A — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2024-0003

Critical vulnerability in multiple SICK products

SICK — CLV

SICK PSIRTcritical

Published

17 October 2024

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

A critical vulnerability has been discovered in the .sdd files of several SICK products. This vulnerability could allow a remote, unauthenticated attacker to gain access to the "Authorized Client" user role, potentially impacting the availability and integrity of the affected SICK products. Users are strongly urged to change their default passwords immediately.

Mitigation summary

Customers are strongly advised to change their default passwords.

Revision history (3)
  1. Initial publication — 17 October 2024

    Initial version

  2. Update A — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  3. Update B — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2021-0001

Inadequate SSH configuration in SICK Visionary-S CX

SICK — Visionary-S CX

SICK PSIRTlow

Published

26 June 2021

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

SICK received a report that informed SICK about an Inadequate Encryption Strength vulnerability in the SICK product “SICK Visionary-S CX” concerning the internal SSH interface solely used by SICK for recovering returned devices. Currently SICK is not aware of any public exploits specifically targeting this vulnerability.

Mitigation summary

Update to version 5.21.2.29154R or higher

Revision history (4)
  1. Initial publication — 26 June 2021

    Initial Release

  2. Update A — 9 February 2023

    Updated Advisory (only visual changes)

  3. Update B — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  4. Update C — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2021-0004

Vulnerabilities in SICK SOPAS ET

SICK — SOPAS Engineering Tool

SICK PSIRThigh

Published

17 December 2021

Last update

13 November 2026

Affected sectors

Risk evaluation

SICK received a report from Eden Bar of Claroty about multiple security vulnerabilities in the SICK SOPAS ET software. An unauthorized attacker could potentially craft a malicious SOPAS Device Driver (SDD) file, that if a user imports that file to SOPAS ET could allow arbitrary code execution on the target system. Currently SICK is not aware of any public exploits specifically targeting any of the vulnerabilities. SICK has released a new version of the SICK SOPAS ET software and recommends updating to the newest version.

Mitigation summary

Update to at least version 4.8.0

Revision history (4)
  1. Initial publication — 17 December 2021

    Initial Release

  2. Update A — 10 February 2023

    Updated Advisory (only visual changes)

  3. Update B — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  4. Update C — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2025-0001

Multiple vulnerabilities in SICK MEAC300

SICK — MEAC

SICK PSIRTcritical

Published

14 February 2025

Last update

13 November 2026

Affected sectors

Risk evaluation

SICK has identified vulnerabilities in MEAC300. These vulnerabilities, related to the OpenSSL library and specific device functionalities, could potentially allow remote, unauthenticated attackers to: 1) Cause a denial of service: Triggering an infinite loop that consumes CPU resources, rendering the device unresponsive (CVE-2022-0778). This impacts MEAC300 DE devices running vulnerable OpenSSL versions when processing manipulated SSH certificates. 2) Compromise the MEAC300: Exploit vulnerabilities accessible via Ethernet to potentially impact the availability, integrity, and confidentiality of the device. SICK recommends ensuring that affected products operate within secure network environments to mitigate these risks.

Mitigation summary

Users are strongly recommended to upgrade to the latest release of the MEAC300 (>=4.0.54.21) that includes a patch for the vulnerability.

Revision history (4)
  1. Initial publication — 14 February 2025

    Initial version

  2. Update A — 21 February 2025

    Fix provided for CVE-2025-0867

  3. Update B — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  4. Update C — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2025-0014

CodeMeter vulnerablity affects SICK CODE-LOC and SICK LIDAR-LOC

SICK — CODE-LOC

SICK PSIRThigh

Published

3 November 2025

Last update

13 November 2026

Linked CVEs

Affected sectors

Control centres

Risk evaluation

A vulnerability in the CodeMeter runtime affects the SICK products SICK CODE-LOC and SICK LIDAR-LOC. This could potentially affect the integrity, confidentiality and availability of the products. Only systems running on Microsoft Windows are affected. Furthermore, the systems are only affected when running the installation and keeping the Control Center component open. As soon as the system has been restarted, it is no longer affected by the vulnerability. Nevertheless, SICK strongly recommends to upgrade to the latest version of the products to mitigate the risk. Currently, SICK is not aware of any public exploits.

Mitigation summary

On Microsoft Windows systems, it is strongly recommended to upgrade to the latest version (LLS-2.8.1.24092R).

Revision history (2)
  1. Initial publication — 3 November 2025

    Initial version

  2. Update A — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2025-0012

Sudo vulnerability affects SICK SID products

SICK — Sensor Integration Display

SICK PSIRTcritical

Published

27 October 2025

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

SICK SID products are affected by the sudo vulnerability CVE-2025-32463. SICK strongly recommends to update to the latest version to mitigate the risk.

Mitigation summary

It is strongly recommended to upgrade to the latest version (4.2.7)

Revision history (2)
  1. Initial publication — 27 October 2025

    Initial version

  2. Update A — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2025-0003

FreeRTOS Vulnerabilities have no impact on SICK Products

SICK — deTem

SICK PSIRTcritical

Risk evaluation

FreeRTOS has several known vulnerabilities and is used in various SICK products. A current analysis confirms that the identified vulnerabilities in FreeRTOS do not affect the mentioned SICK products. At this time, there is no indication of any potential risks to these SICK products.

Mitigation summary

See the official CISA advisory for mitigating measures.

Revision history (4)
  1. Initial publication — 28 February 2025

    Initial version

  2. Update A — 20 May 2025

    Added two products: ANS58 and ANM58. Both have the product status 'Known Not Affected'.

  3. Update B — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  4. Update C — 17 April 2026

    Added product: DCM4 (status: known not affected) and adjusted version ranges for: DMM4, deTec4, deTem4, deTem4 A/P (all versions marked as known not affected)

Official source: SICK PSIRT

SCA-2025-0004

Critical vulnerabilities in SICK DL100-2xxxxxxx

SICK — Dx100

SICK PSIRTcritical

Published

14 March 2025

Last update

13 November 2026

Affected sectors

Risk evaluation

Critical vulnerabilities have been found in the SICK device DL100-2xxxxxxx. If exploited, this potentially allows an attacker to impact availabiltiy, integrity and confidentaility of the products. Currently, SICK is not aware of any public exploits specifically targeting these vulnerabilities. As a mitigation, SICK strongly recommends operating the system within a secure infrastructure to minimize risk.

Mitigation summary

Please make sure that you apply general security practices when operating the products. The following General Security Practices and Operating Guidelines could mitigate the associated security risk.

Revision history (3)
  1. Initial publication — 14 March 2025

    Initial version

  2. Update A — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  3. Update B — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

SCA-2020-0004

Vulnerability in Platform Mechanism AutoIP

SICK — CLV62x

SICK PSIRThigh

Published

29 October 2020

Last update

13 November 2026

Linked CVEs

Affected sectors

Risk evaluation

SICK received a report from IOActive that informed SICK about a security vulnerability within the platform mechanism AutoIP, used by multiple devices. SICK recommends updating to the newest version. Refer to the recommended remediations for affected products where no update is available. Currently SICK is not aware of any public exploits specifically targeting this vulnerability.

Mitigation summary

Update to version V1.04 SICK removed the AutoIP weakness with the same available fix for the MSC800. The update can only be implemented by a SICK service technician, either by remote access or on site. To obtain the update, please contact your local service technician.

Revision history (4)
  1. Initial publication — 29 October 2020

    Initial Release

  2. Update A — 10 February 2023

    Updated Advisory (only visual changes)

  3. Update B — 30 July 2025

    Updated Advisory: URL for SICK Operating Guidelines has been updated

  4. Update C — 13 November 2026

    Corrected initial_release_date to match the date of the initial revision (revision 1). No changes to vulnerability, product, or remediation information.

Official source: SICK PSIRT

3KXG141033R4801

ACF5000 LCS/CCUS PHP2Shell and OpenSSL Vulnerabilities

ABB — ACF5000 LCS

ABB PSIRTcritical

Published

12 November 2026

Last update

12 November 2026

Affected sectors

Risk evaluation

An update is available that resolves the publicly reported vulnerabilities in the PHP and OpenSSL components in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could insert and run arbitrary code. An attacker who successfully exploited the OpenSSL vulnerability (CVE-2026-35189) could cause a denial of service of the affected products.

Mitigation summary

The vulnerabilities are fixed with the following product version: 5.6.2. ABB recommends that customers apply the update at earliest convenience. Physical access to the ACF5000 LCS/CCUS for the update procedure is strongly recommended. The ACF5000 LCS will re-boot during the update procedure and the gas measurement will be interrupted. ABB advises not to perform the update if - the ACF5000 LCS/CCUS is performing critical measurements, and the interruption of the measurement is not acceptable. - the customer does not feel confident in performing the update themselves. Update procedure: 1. Download the latest version of the SMT for ACF5000 software using the ABB Library. Please refer to the reference section for the download link (SMT for ACF5000 software). 2. Run SMT and connect the ACF5000 LCS/CCUS via Ethernet cable to the computer running SMT. 3. Follow the steps outlined in the SMT user manual. ABB recommends performing the update step-by-step (Save configuration data, Load new software, Load configuration data). Please refer to the reference section for the download link (SMT user manual). 4. Verify that all connections to DCS and/or Data Acquisition Handling systems are established and correct. 5. In case the remote connection (AO-HMI for ACF5000) was used, it needs to be updated to match the ACF5000 LCS/CCUS software version. Please refer to the reference section for the download link (AO-HMI for ACF5000). In case an update is not possible or the customer prefers the update to be performed by a service technician, ABB strongly recommends setting the web server of the ACF5000 LCS/CCUS to be available on interface “X8” only, as described in section “Workarounds”. The ACF5000 LCS/CCUS is designed to be operated in an isolated network segment as described in section “Mitigating factors”.

Revision history (1)
  1. Initial publication — 12 November 2026

    Initial version.

Official source: ABB PSIRT

VDE-2026-138

Welotec: Trust in Compromised Intermediate Certificates in egOS

Welotec — Edge Gateways

Welotec PSIRTmiddel

Published

11 November 2026

Last update

11 November 2026

Linked CVEs

Affected sectors

Risk evaluation

The egOS system trust store uses certificate data from the Mozilla NSS root store. The trust store contains eMudhra emSign root certificates associated with eight compromised intermediate certificate authority keys. An unauthenticated attacker who possesses one of the compromised keys and can intercept relevant network traffic may issue fraudulent TLS certificates, impersonate remote services, and read or modify outgoing TLS traffic from the device.

Mitigation summary

There is no supported customer-performable workaround for removing the affected certificates from the devices. Until the fixed egOS version can be installed, restrict egOS communication to trusted networks and use network segmentation or a trusted VPN where operationally possible. Prevent untrusted parties from gaining a man-in-the-middle position on network paths used by the affected devices. Monitor affected devices and connected services for unexpected TLS endpoints, certificate changes, and anomalous network activity.

Revision history (1)
  1. Initial publication — 11 November 2026

    Initial release.

Official source: Welotec PSIRT

VDE-2026-087

Beckhoff: Exposed IOCTLs with insufficient access control in TcRouter.sys

Beckhoff — TwinCAT 3.1 driver

Beckhoff PSIRThigh

Published

11 November 2026

Last update

11 November 2026

Affected sectors

Risk evaluation

The vulnerabilities allow local low privileged users or processes to gain full system access on the affected devices through exposed IOCTL function calls.

Mitigation summary

Please update to a recent version of the affected components.

Revision history (1)
  1. Initial publication — 11 November 2026

    Initial revision.

Official source: Beckhoff PSIRT

4JXD000118

ABB Ability™ OPTIMAX® Node2Shell

ABB — ABB Ability™ OPTIMAX®

ABB PSIRTcritical

Published

11 November 2026

Last update

11 November 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to insert and run arbitrary code.

Mitigation summary

The problem is corrected in the following product version: - ABB Ability™ OPTIMAX®, 6.4.1 OS Patch. Optional but recommended (don_osupdate_v6.4.1-release-date) OPTIMAX patch (OPTIMAX_v6.4.1+ release-date.iso) ABB recommends that customers apply the update at earliest convenience. A technical note will be made available to ABB customers via ABB Library describing the patching instructions.

Revision history (1)
  1. Initial publication — 11 November 2026

    Initial version.

Official source: ABB PSIRT

4JXD000117

ABB Ability™ OPTIMAX® Use-after-free - kernel IPv4

ABB — ABB Ability™ OPTIMAX®

ABB PSIRTcritical

Published

11 November 2026

Last update

11 November 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to insert and run arbitrary code.

Mitigation summary

The problem is corrected in the following product version: - ABB Ability™ OPTIMAX®, 6.4.x OS Patch: don_osupdate_v6.4.1-261107 ABB recommends that customers apply the update at earliest convenience. A technical note describing the patching instructions will be made available to ABB customers via ABB Library.

Revision history (1)
  1. Initial publication — 11 November 2026

    Initial version.

Official source: ABB PSIRT

VDE-2026-152

Weidmueller: Security routers IE-SR-4TX and IE-SR-4GT affected by PHP vulnerability

Weidmüller — IE-SR

Weidmüller PSIRTcritical

Published

10 November 2026

Last update

10 November 2026

Linked CVEs

Affected sectors

Risk evaluation

The Weidmueller security routers IE-SR-4TX and IE-SR-4GT in firmware releases prior to 2.3.4 bundle a PHP version that is affected by CVE-2026-109618. In the configuration used by the products, the vulnerability can allow an attacker to cause a denial of service by making the web interface temporarily unavailable. All other functions (Routing, Firewall etc.) are not affected. It is fixed in firmware 2.3.4. CVE-2026-109619, which was published together with CVE-2026-109618, does not affect the products.

Mitigation summary

Restrict access to the web interface to trusted networks.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial version

Official source: Weidmüller PSIRT

VDE-2026-079

MB connect line: Multiple Vulnerabilities in mbCONNECT24/mymbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRTcritical

Risk evaluation

Multiple vulnerabilities have been discovered in MB connect line mbCONNECT24/mymbCONNECT24 that could allow RCE, DoS or information leakage.

Mitigation summary

Update the mbCONNECT24/mymbCONNECT24 instance to version 2.21.0.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial revision.

Official source: MB connect line PSIRT

VDE-2026-128

MB connect line: php2shell in mbCONNECT24/mymbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRTcritical

Published

10 November 2026

Last update

10 November 2026

Affected sectors

Risk evaluation

MB connect line mbCONNECT24/mymbCONNECT24 ships with a bundled PHP version that is affected by two vulnerabilities known as "php2shell".

Mitigation summary

Update the mbCONNECT24/mymbCONNECT24 instance to version 2.21.6.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial revision.

Official source: MB connect line PSIRT

VDE-2026-141

Helmholz: Multiple Vulnerabilities in myREX24V2/myREX24V2.virtual

Helmholz — myREX24V2

Helmholz PSIRTcritical

Risk evaluation

Multiple vulnerabilities have been discovered in Helmholz myREX24V2/myREX24V2.virtual that could allow RCE, DoS or information leakage.

Mitigation summary

Update the myREX24V2/myREX24V2.virtual instance to version 2.21.0.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial revision.

Official source: Helmholz PSIRT

VDE-2026-160

Helmholz: php2shell in myREX24V2/myREX24V2.virtual

Helmholz — myREX24V2

Helmholz PSIRTcritical

Published

10 November 2026

Last update

10 November 2026

Affected sectors

Risk evaluation

Helmholz myREX24V2/myREX24V2.virtual ships with a bundled PHP version that is affected by two vulnerabilities known as "php2shell".

Mitigation summary

Update the myREX24V2/myREX24V2.virtual instance to version 2.21.6.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial revision.

Official source: Helmholz PSIRT

VDE-2026-143

Bender EDGE500IP Vulnerabilities - Linux Kernel (TLS and AF_ALG)

Bender — EDGE500IP

Bender PSIRTcritical

Published

10 November 2026

Last update

10 November 2026

Affected sectors

Risk evaluation

Bender is publishing this advisory to inform customers about two vulnerabilities in the Linux kernel used by the EDGE500IP. CISA has added both vulnerabilities (CVE-2025-39682 and CVE-2025-39964) to its Known Exploited Vulnerabilities catalog. Bender has analyzed the vulnerabilities and determined that the electrical safety of the devices is not affected. Exploitation on the EDGE500IP requires code execution on the device, which is not available to users. Bender nevertheless considers the vulnerabilities to be of medium risk and has fixed them in COMTRAXX firmware 5.1.1.

Mitigation summary

Fixed upstream in Linux kernel 6.6.103. For the EDGE500IP the fix is backported in COMTRAXX firmware 5.1.1.

Revision history (1)
  1. Initial publication — 10 November 2026

    Initial revision.

Official source: Bender PSIRT

SEVD-2026-314-01

Use After Free vulnerability on EcoStruxure™ Power Build Rapsody

Schneider Electric — EcoStruxure Power Build Rapsody software

Schneider Electric CPCERTmiddel

Published

10 November 2026

Last update

10 November 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its EcoStruxure™ Power Build Rapsody product. The EcoStruxure™ Power Build Rapsody is used to enter or import the single line diagram, to get the extensive bill of material of your switchboard, including all devices, connection items, and mounting components Failure to apply the remediations provided below may risk memory corruption, heap-based buffer overflow, and/or stack-based buffer overflow, which could result in local attackers being able to exploit these issues to potentially execute arbitrary code.

Mitigation summary

Versions FR V2.9.12.0101, ESP V2.9.5.0000, PT V2.9.7.0000, BEL(FR) V2.9.8.0000, BEL(EN) V2.9.3.0000, INT(EN) V2.9.4.0000, INT(FR)V2.9.6.0000, NL V2.9.6.0000 of EcoStruxure™ Power Build Rapsody software includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=2309

Revision history (1)
  1. Initial publication — 10 November 2026

    Original Release

Official source: Schneider Electric CPCERT

SSA-104023

SSA-104023: Multiple Vulnerabilities in Palo Alto Networks PAN-OS on RUGGEDCOM APE1808 Devices

Siemens — RUGGEDCOM APE1808

Siemens ProductCERTcritical

Risk evaluation

Palo Alto Networks has published [1] information on vulnerabilities in PAN-OS. This advisory lists the related Siemens Industrial products affected by these vulnerabilities. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/

Mitigation summary

Contact customer support to receive patch and update information

Revision history (4)
  1. Initial publication — 14 July 2026

    Publication Date

  2. Update A — 11 August 2026

    Added CVE-2026-0279, CVE-2026-0280, CVE-2026-0281, CVE-2026-0282, CVE-2026-0283, CVE-2026-0284, CVE-2026-0285, CVE-2026-0286, CVE-2026-0287 and CVE-2026-0288

  3. Update B — 13 October 2026

    Added CVE-2026-0308, CVE-2026-0309 and CVE-2026-0310

  4. Update C — 10 November 2026

    Added CVE-2026-0316, CVE-2026-0317, CVE-2026-0318, CVE-2026-0319, CVE-2026-0320, CVE-2026-0321 and CVE-2026-0322

Official source: Siemens ProductCERT

SSA-105852

SSA-105852: Out of Bounds Read Vulnerability in Simcenter Femap

Siemens — Simcenter Femap

Siemens ProductCERThigh

Published

10 November 2026

Last update

10 November 2026

Linked CVEs

Affected sectors

Risk evaluation

Simcenter Femap is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

Mitigation summary

Update to V2606.0002 or later version

Revision history (1)
  1. Initial publication — 10 November 2026

    Publication Date

Official source: Siemens ProductCERT