VDE-2021-016

Weidmueller: Accidentally open network port in u-controls and IoT-Gateways

Weidmüller — IOT-GW30

Weidmüller PSIRTcritical

Published

4 May 2021

Last update

14 May 2025

Linked CVEs

Affected sectors

Risk evaluation

A network port intended only for device-internal usage is accidentally accessible via external network interfaces.

Mitigation summary

Restrict access to the network th device is connected to Do not directly connect the device to the internet

Revision history (2)
  1. Initial publication — 4 May 2021

    Initial revision.

  2. Update A — 14 May 2025

    Fix: version space, firmware category, added distribution

Official source: Weidmüller PSIRT

VDE-2020-041

Weidmueller: u-create studio < 1.20.2 affected by WIBU-SYSTEMS CodeMeter vulnerabilities

Weidmüller — u-create studio

Weidmüller PSIRTcritical

Published

12 October 2020

Last update

14 May 2025

Affected sectors

Risk evaluation

WIBU-SYSTEMS report multiple vulnerabilities in their CodeMeter Runtime software. As part of the Weidmüller u-create studio installation the WIBU-SYSTEMS CodeMeter is installed by default. As the u-create studio installation bundle contains vulnerable versions of WIBU-SYSTEMS CodeMeter, the u-create studio is affected by a subset of these vulnerabilities. For details refer to section "Impact".

Mitigation summary

- Use the updated versions of the TRUMPF CAD/CAM products that will be available via your service channel shortly. - Until then, reduce internet usage on workstations with TRUMPF CAD/CAM products to a minimum.

Revision history (2)
  1. Initial publication — 12 October 2020

    Initial revision.

  2. Update A — 14 May 2025

    Fix: firmware category, reference category, added distribution

Official source: Weidmüller PSIRT

VDE-2021-040

Endress+Hauser: Promass 83 with EtherNet/IP affected by a stack-based buffer overflow

Endress+Hauser — Promass 83

Endress+Hauser PSIRTcritical

Published

4 October 2021

Last update

14 May 2025

Linked CVEs

Affected sectors

Risk evaluation

Promass 83 devices utilizing 499ES EtherNet/IP (ENIP) Stack by Real Time Automation (RTA) are vulnerable to a stack-based buffer overflow. Update A, 2021-10-07: added credits changed title from "ENDRESS+HAUSER: Promass 83 with Ether/IP affected by DoS vulnerability" to "ENDRESS+HAUSER: Promass 83 with EtherNet/IP affected by a stack-based buffer overflow"

Mitigation summary

If an immediate firmware update is not possible, the only way to prevent an attack is to disable communication via EtherNet/IP.

Revision history (3)
  1. Initial publication — 4 October 2021

    Initial revision.

  2. Update A — 7 October 2021

    Update A

  3. Update B — 14 May 2025

    Fix: firmware category, added distribution

Official source: Endress+Hauser PSIRT

VDE-2021-010

Endress+Hauser: products utilizing WPA2 vulnerable to KRACK attacks

Endress+Hauser — Promag

Endress+Hauser PSIRTmiddel

Published

18 May 2021

Last update

14 May 2025

Affected sectors

Risk evaluation

Endress+Hauser products utilizing WPA2 are vulnerable to KRACK attacks. Proline portfolio is a flow meter with an optional WLAN interface in the display. The flowmeters are only affected if the optional WLAN display is present.

Mitigation summary

If an immediate firmware update is not possible, the WLAN on the unit can also be switched off as a precautionary measure.

Revision history (2)
  1. Initial publication — 15 May 2021

    Initial revision.

  2. Update A — 14 May 2025

    Fix: version space, added distribution

Official source: Endress+Hauser PSIRT

VDE-2021-031

MB connect line: Apache Guacamole related vulnerabilities in mbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRTmiddel

Published

22 July 2021

Last update

14 May 2025

Affected sectors

Risk evaluation

Two vulnerabilities in mbCONNECT24 and mymbCONNECT24 can lead to information disclosure and arbitrary code execution. Please consult the CVE entries for details.

Mitigation summary

Update to 3.9R0.5

Revision history (2)
  1. Initial publication — 22 July 2021

    Initial revision.

  2. Update A — 14 May 2025

    Fix: version space, added distribution

Official source: MB connect line PSIRT

VDE-2021-037

MB connect line: Remote user enumeration in mbCONNECT24/mymbCONNECT24

MB connect line — mbCONNECT24

MB connect line PSIRThigh

Published

27 October 2021

Last update

14 May 2025

Linked CVEs

Affected sectors

Risk evaluation

An issue was discovered in the mymbCONNECT24 and mbCONNECT24 software in all versions through V2.9.0.

Mitigation summary

Update mbCONNECT24/mymbCONNECT24 to 2.10.1

Revision history (2)
  1. Initial publication — 27 October 2021

    Initial revision.

  2. Update A — 14 May 2025

    Fix: firmware category

Official source: MB connect line PSIRT

VDE-2021-017

MB connect line: Privilege escalation in mbDIALUP

MB connect line — mbDIALUP

MB connect line PSIRTcritical

Published

22 July 2021

Last update

14 May 2025

Affected sectors

Risk evaluation

Multiple Vulnerabilities in mbConnect24serv (a software service of mbDIALUP) can lead to arbitrary code execution due to improper privilege management. Update A, 2021-11-24 corrected fixed version in solution from 3.9R0.4 to 3.9R0.5 Update B, 2022-03-28 Updated CVSS score from CVE-2021-33527 from 7.8 to 9.8 due to new information about the vulnerability

Mitigation summary

Update to 3.9R0.5

Revision history (4)
  1. Initial publication — 22 July 2021

    Initial revision.

  2. Update A — 24 November 2021

    Update A

  3. Update B — 28 March 2022

    Update B

  4. Update C — 14 May 2025

    Fix: version space, added distribution

Official source: MB connect line PSIRT

VDE-2021-012

MB connect line: multiple products partially affected by DNSpooq

MB connect line — mbNET HW1

MB connect line PSIRTlow

Published

26 April 2021

Last update

14 May 2025

Affected sectors

Risk evaluation

Multiple issues have been identified in dnsmasq < 2.83

Mitigation summary

Update to the following versions: | Product | Fixed Version | |--------------------|-------------------| | mbNET/mbNET .rokey | >= 7.0.0 | | mbNET HW1 | >= 5.1.11 |

Revision history (2)
  1. Initial publication — 26 April 2021

    Initial revision.

  2. Update A — 14 May 2025

    Fix: version space

Official source: MB connect line PSIRT

VDE-2024-044

Helmholz: Multiple products are vulnerable to regreSSHion

Helmholz — myREX24 V2

Helmholz PSIRThigh

Published

31 July 2024

Last update

14 May 2025

Linked CVEs

Affected sectors

Risk evaluation

Several Helmholz products are vulnerable to a possible race condition vulnerability in OpenSSH named "regreSSHion".

Mitigation summary

Prevent all access to the sshd daemon listening on port 22.

Revision history (2)
  1. Initial publication — 31 July 2024

    initial revision

  2. Update A — 14 May 2025

    Fix: version space, added distribution

Official source: Helmholz PSIRT

FSA-202305

Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in several products

Festo — MES-PC

Festo PSIRTcritical

Published

28 November 2023

Last update

13 May 2025

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the Wibu CodeMeter Runtime, which is part of the installation packages of several Festo products, was found. An attacker exploiting the vulnerability in WIBU CodeMeter Runtime in server mode could gain full access to the affected server via network access without any user interaction. This could lead to remote code execution and escalation of privileges giving full admin access on the host system for an already authenticated user (logged in locally to the PC).

Mitigation summary

Update CodeMeter Runtime to version >= 7.60c The latest version of CodeMeter Runtime can be downloaded from WIBU System's web site.

Revision history (3)
  1. Initial publication — 28 November 2023

    Initial version

  2. Update A — 5 December 2023

    Removed 'MES4 (v3)', 'MES4 (<=v2)' and 'Energy-PC' from affected products as they do not install WIBU CodeMeter Runtime.

  3. Update B — 13 May 2025

    Adjusted to VDE template and updated information on fixed version of the Festo Automation Suite. Changed document title from 'Vulnerable Wibu CodeMeter Runtime in Several Festo Products' to 'Festo: Vulnerable WIBU-SYSTEMS CodeMeter Runtime in several products'. Updated legal disclaimer to add references to special provisions.

Official source: Festo PSIRT

VDE-2025-024

Wiesemann & Theis: Multiple products from Wiesemann & Theis support deprecated jQuery version

Wiesemann & Theis — USB-Server Industry Isochron

Wiesemann & Theis PSIRTmiddel

Published

13 May 2025

Last update

13 May 2025

Linked CVEs

Affected sectors

Risk evaluation

Multiple W&T devices are shipped with a jQuery version with a known XSS vulnerability.

Mitigation summary

Access to the WBM should be limited to trustworthy networks or peers.

Revision history (1)
  1. Initial publication — 13 May 2025

    Initial revision

Official source: Wiesemann & Theis PSIRT

VDE-2025-032

Wiesemann & Theis: Multiple W&T Products are vulnerable to cross-site-scripting

Wiesemann & Theis — Web-IO Analog-In/Out 0/4..20mA PoE

Wiesemann & Theis PSIRTmiddel

Published

6 May 2025

Last update

6 May 2025

Linked CVEs

Affected sectors

Risk evaluation

Multiple W&T Products are prone to an XSS attack. An authenticated remote Attacker can execute arbitrary web scripts or HTML via crafted payloads injected into several input fields of the configuration webpage.

Mitigation summary

Access to the WBM should be limited to trustworthy networks or peers.

Revision history (1)
  1. Initial publication — 6 May 2025

    Initial revision

Official source: Wiesemann & Theis PSIRT

VDE-2025-031

Wiesemann & Theis: Multiple products from Wiesemann & Theis support deprecated TLS protocol versions

Wiesemann & Theis — Com-Server ++

Wiesemann & Theis PSIRTcritical

Published

28 April 2025

Last update

28 April 2025

Linked CVEs

Affected sectors

Risk evaluation

Com-Server firmware versions prior to 1.60 support the insecure TLS 1.0 and TLS 1.1 protocols, which are susceptible to man-in-the-middle attacks and thereby compromise the confidentiality and integrity of data.

Mitigation summary

Access to the WBM should be limited to trustworthy networks or peers.

Revision history (1)
  1. Initial publication — 28 April 2025

    Initial revision

Official source: Wiesemann & Theis PSIRT

VDE-2020-021

Endress+Hauser: Ecograph T utilizing Webserver firmware version 1.x suffers from improper privilege management

Endress+Hauser — Ecograph T Neutral/Private Label

Endress+Hauser PSIRThigh

Published

19 November 2020

Last update

11 April 2025

Linked CVEs

Affected sectors

Risk evaluation

The affected device has a web-based user interface with a role-based access system. Users with different roles have different write and read privileges. The access system is based on dynamic "tokens".

Mitigation summary

Customers should configure a perimeter firewall to block traffic from untrusted networks and users to the device. These recommendations will be incorporated into the device documentation (operating instructions). Change default password for operator, service and admin account. Endress+Hauser will not change this behavior. Customers are recommended to take the measures for Temporary Fix / Mitigation as described above.

Revision history (2)
  1. Initial publication — 19 November 2020

    Initial revision.

  2. Update A — 11 April 2025

    Fix: version range

Official source: Endress+Hauser PSIRT

VDE-2024-064

Beckhoff: Local command injection via TwinCAT Package Manager

Beckhoff — TwinCAT Package Manager

Beckhoff PSIRTmiddel

Published

31 October 2024

Last update

11 April 2025

Linked CVEs

Affected sectors

Risk evaluation

Beckhoff's TwinCAT 3.1 Build 4026 software is modularized and is installed with different packages depending on user requirements. These packages are selected and installed using either the command line utility tcpkg or the corresponding graphical user interface called TwinCAT Package Manager. Both use the same configuration that specifies where to load packages from. These locations are called feeds, have preconfigured default settings and can be customized by administrative users, for example to add another local mirror of a package server. When using the TwinCAT Package Manager on a PC, a user with administrative access rights can locally set a specially crafted URL for a feed that causes the TwinCAT Package Manager to execute arbitrary operating system commands.

Mitigation summary

Administrative users shall always act thoroughly and inspect the values which they enter.

Revision history (3)
  1. Initial publication — 31 October 2024

    initial revision

  2. Update A — 16 January 2025

    Fix: list of branches, references

  3. Update B — 11 April 2025

    Fix: version range

Official source: Beckhoff PSIRT

VDE-2023-050

Pilz: Vulnerability in PASvisu and PMI v8xx

Pilz — PMI v8xx

Pilz PSIRThigh

Published

30 January 2024

Last update

10 April 2025

Affected sectors

Risk evaluation

Multiple Pilz products are affected by stored cross-site-scripting (XSS) vulnerabilities. The vulnerabilities may enable an attacker to gain full control over the system. Update: 27.02.2024 Fix typo in advisory title

Mitigation summary

* Only use project files from trustworthy sources. * Protect project files against modification by unauthorized users. * PASvisu Runtime: Limit network access to legitimate connections by using a firewall or similar measures. Use password protection on the online project.

Revision history (4)
  1. Initial publication — 30 January 2024

    Initial revision.

  2. Update A — 27 February 2024

    Updated Title.

  3. Update B — 6 November 2024

    Fix: correct certvde domain, added self-reference

  4. Update C — 10 April 2025

    fixed version operators

Official source: Pilz PSIRT

VDE-2024-040

Multiple TRUMPF products prone to regreSSHion OpenSSH server vulnerabilities

TRUMPF — TruPulse

TRUMPF PSIRThigh

Published

25 June 2024

Last update

10 April 2025

Linked CVEs

Affected sectors

Risk evaluation

TruControl laser control software prior to version 1.60.0 uses an OpenSSH server version affected by CVE-2024-6387. The affected OpenSSH Server version could potentially lead to a remote code execution.

Mitigation summary

Update to first fixed version 1.06.00 or ideally to the newest release 04.04.00

Revision history (4)
  1. Initial publication — 25 June 2024

    Initial revision.

  2. Update A — 6 November 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 14 November 2024

    removed issuing authority as it is the same as the publisher

  4. Update C — 10 April 2025

    Fixed CSAF self-reference URL

Official source: TRUMPF PSIRT

VDE-2024-034

Multiple TRUMPF products prone to nftables server vulnerabilities

TRUMPF — Laser SE TruPulse

TRUMPF PSIRThigh

Published

25 June 2024

Last update

10 April 2025

Linked CVEs

Affected sectors

Risk evaluation

TruControl laser control software from versions 3.50.0 to 4.00.0.B use Linux kernel versions affected by CVE-2024-1086. The affected kernel vulnerability could lead to local privilege escalation.

Mitigation summary

• Update to the new release 4.04.0 of the TruControl software version

Revision history (3)
  1. Initial publication — 25 June 2024

    Initial revision.

  2. Update A — 6 November 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 10 April 2025

    Fixed CSAF self-reference URL

Official source: TRUMPF PSIRT

VDE-2025-003

WAGO: Vulnerability in WAGO Profinet IO Coupler 0750-0375

WAGO — 750 Fieldbus Coupler

WAGO PSIRTcritical

Published

24 March 2025

Last update

24 March 2025

Linked CVEs

Affected sectors

Risk evaluation

The Fraunhofer Institute discovered a vulnerability in the Profinet IO Coupler 0750-0375 during fuzzing tests. These tests revealed weaknesses in the validation and processing of incoming data packets across various protocols and services.

Mitigation summary

Update to firmware version 02.10.01 (12).

Revision history (1)
  1. Initial publication — 11 March 2025

    Initial release.

Official source: WAGO PSIRT

VDE-2024-053

Lenze: Install Directory with insufficient permissions

Lenze — EASY UI Designer

Lenze PSIRThigh

Published

3 September 2024

Last update

13 March 2025

Linked CVEs

Affected sectors

Risk evaluation

The following tools: * VisiWinNET Smart * VisiWinNET Professional * EASY UI Designer create a directory with insufficient permissions, allowing a low-level user the ability to add and modify certain files that hold SYSTEM privileges, which could lead to privilege escalation.

Mitigation summary

Only use this tool in a protected and controlled environment to minimize network impact and to ensure that the tool is inaccessable from outside. In addition, the use of firewalls is recommended to reduce the attack surface, specially to the internet and the internal business network.

Revision history (3)
  1. Initial publication — 21 August 2024

    Initial revision.

  2. Update A — 6 November 2024

    Fix: correct certvde domain, added self-reference

  3. Update B — 13 March 2025

    Fix: product version

Official source: Lenze PSIRT

VDE-2025-036

Multiple vulnerabilities in Endress+Hauser MEAC300-FNADE4

Endress+Hauser — MEAC

Endress+Hauser PSIRThigh

Risk evaluation

Several vulnerabilities in the Endress+Hauser MEAC300-FNADE4 were discovered, that can be accessed via Ethernet.

Mitigation summary

Customers are strongly advised to update to the newest version.

Revision history (1)
  1. Initial publication — 6 March 2025

    Initial version

Official source: Endress+Hauser PSIRT

VDE-2025-023

Weidmueller: OpenSSL vulnerability in industrial ethernet switches

Weidmüller — IE-SW

Weidmüller PSIRThigh

Published

5 March 2025

Last update

5 March 2025

Linked CVEs

Affected sectors

Risk evaluation

Multiple Weidmueller products are affected by an OpenSSL vulnerability. Weidmüller has released new firmwares of the affected products to fix the vulnerability.

Mitigation summary

Update to version V3.6.30

Revision history (2)
  1. Initial publication — 5 March 2025

    Initial version

  2. Update A — 5 March 2025

    added categories to references

Official source: Weidmüller PSIRT

VDE-2025-004

Vulnerability in libwagosnmp

WAGO — CC100

WAGO PSIRTmiddel

Published

5 March 2025

Last update

5 March 2025

Linked CVEs

Affected sectors

Risk evaluation

Nozomi Networks reported a vulnerability in the pfc firmware sdk-G2 of libwagosnmp. The WAGO pfc-firmware-sdk-G2 is a software development kit designed for WAGO PFC devices which developers to build and customize the firmware.

Mitigation summary

Update to Firmware 04.07.01 (FW29) or Firmware 03.10.11 (FW22 Patch 2). For the latest Custom Firmware, please contact the WAGO support.

Revision history (1)
  1. Initial publication — 5 March 2025

    Initial release.

Official source: WAGO PSIRT

VDE-2025-009

WAGO: Vulnerabilities in CODESYS Control V3 - OPC UA Stack

WAGO — CC100

WAGO PSIRThigh

Published

4 February 2025

Last update

4 March 2025

Linked CVEs

Affected sectors

Risk evaluation

Several WAGO Firmwares are vulnerable, due to an incorrect calculation of the buffer size in the CODESYS OPC UA STACK. This can lead to a crash of the runtime of the following firmware versions installed on several devices.

Mitigation summary

The incorrect calculation of the buffer size can be avoided if the maximum supported array length of the OPC UA stack of the CODESYS Control runtime system is limited to a value of 10129639 (Stack.MaxArrayLenth=10129639) or less. This can be achieved by adding the following setting in the runtime configuration under the following path: /etc/codesys3.d/codesyscotrol.cfg

Revision history (1)
  1. Initial publication — 4 February 2025

    Initial release.

Official source: WAGO PSIRT

FSA-202406

Several Codesys Gateway v2 vulnerabilities in Codesys provided by Festo

Festo — CODESYS provided by Festo

Festo PSIRTcritical

Published

3 December 2024

Last update

3 December 2024

Affected sectors

Risk evaluation

An unauthenticated attacker would be able to send crafted requests to cause the CODESYS Gateway Server V2 to allocate excessive memory or consume all available TCP client connections. Besides, passwords are insufficiently checked during login. All versions of the following CODESYS V2 product prior version V2.3.9.38 are affected: • CODESYS Gateway Server

Mitigation summary

Enable password protection at login in case no password is set at the controller. Please note that the password configuration file is not covered by the default FFT backup and restore mechanism. You must select the related file manually.

Revision history (2)
  1. Initial publication — 3 December 2024

    Initial version

  2. Update A — 3 December 2024

    One reference has been corrected

Official source: Festo PSIRT