Skip to content
IACS RadarIndustrial Cyber Exposure & Intelligence

CISA + vendors

ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

499

Found

Advisory data: live connection— last retrieved: 20 November 2026 at 20:17.

Filters

499 advisories found

ICSA-26-211-07

Mitsubishi Electric CC-Link IE TSN Communication Protocol (Update B)

Mitsubishi Electric — Mitsubishi Electric MELSEC MX Controller MX-R model MXR300-16

CISAhigh

Published

30 July 2026

Last update

5 November 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow an attacker with access to the same network segment to tamper with communication data in the affected product by sending specially crafted packets under specific timing conditions. This could allow the attacker to cause a denial-of-service (DoS) condition in the affected product by interfering with its control function or causing it to operate incorrectly.

Mitigation summary

For customers using the affected products, please refer to Mitsubishi Electric's security advisory, "https://www.mitsubishielectric.com/psirt/vulnerability/pdf/2026-005_en.pdf" and take the measures described there.

Revision history (4)
  1. Initial publication — 30 July 2026

    Initial Publication

  2. Update A — 30 July 2026

    CISA Republication - Initial CISA Republication of Mitsubishi Electric 2026-005 advisory

  3. Update B — 17 September 2026

    MXF100S-N32, MXF100S-P32, MXF100S-8-N32, MXF100S-8-P32, MXF100S-16-N32, MXF100S-16-P32, LD78G4, and LD78G16 have been added as affected products and MI2532-W, MI2332-W, and NZ2GACP610-60 have been removed from affected products.

  4. Update C — 17 September 2026

    CISA Republication update based on Mitsubishi Electric 2026-005 advisory

Official source: CISA

VDE-2026-102

WAGO: Unauthorized Account Access via Credential Recovery Process

WAGO — Building Cloud Services

WAGO PSIRTcritical

Published

4 November 2026

Last update

4 November 2026

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the authentication and credential recovery process may allow an unauthenticated attacker to bypass intended verification controls during password reset operations. By exploiting this weakness, an attacker could reset credentials for arbitrary user accounts and gain unauthorized access without possessing valid authentication credentials.

Mitigation summary

The vulnerability was remediated in the Building Cloud Service on August 26, and as the service is centrally managed and updated automatically, no customer action is required to apply the security fix. Customers are advised to review user account activity and verify that no passwords have been changed unexpectedly prior to remediation.

Revision history (1)
  1. Initial publication — 4 November 2026

    Initial release.

Official source: WAGO PSIRT

VDE-2026-084

Phoenix Contact: CodeMeter Runtime Security Vulnerabilities in License Validation in the PLCnext Firmware

Phoenix Contact — Catan C1

Phoenix Contact PSIRThigh

Published

4 November 2026

Last update

4 November 2026

Affected sectors

Risk evaluation

This advisory addresses security vulnerabilities in Phoenix Contact products with an integrated CodeMeter Runtime, like PLCnext devices and Virtual Controls. These security vulnerabilities only may occur with versions <8.41a of the integrated software CodeMeter Runtime from Wibu-Systems. Please see listed products to determine which devices and firmware versions are affected.

Mitigation summary

Please check the Phoenix Contact e-Shop regularly to see if the fixed firmware is already available for your specific PLCnext device or Virtual PLCnext Control. The Fix is planned to be integrated in version 2026.0.6 which is planned for Q4/2026.

Revision history (1)
  1. Initial publication — 4 November 2026

    Initial

Official source: Phoenix Contact PSIRT

VDE-2026-098

Phoenix Contact: CodeMeter Runtime Security Vulnerabilities in License Validation for SW Tools

Phoenix Contact — CodeMeter Runtime licensed software components

Phoenix Contact PSIRThigh

Published

4 November 2026

Last update

4 November 2026

Affected sectors

Risk evaluation

This advisory addresses multiple security vulnerabilities in Phoenix Contact products using the software CodeMeter Runtime like licensed desktop software tools. These security vulnerabilities only may occur with CodeMeter Runtime 8.x versions <V8.41a and CodeMeter Runtime 9.x versions <9.10 from Wibu-Systems.

Mitigation summary

Updates for the affected products are planned for Q4 2026. Until the fix is available, please follow the mitigation measures and check the respective product page on the Phoenix Contact website regularly to see if the fix is already available.

Revision history (1)
  1. Initial publication — 4 November 2026

    Initial

Official source: Phoenix Contact PSIRT

VDE-2026-121

Phoenix Contact: GSDX SignatureValue verification, signed plug-in validation bypass and path traversal vulnerabilities in PLCnext Engineer programming software

Phoenix Contact — PLCnext Engineer

Phoenix Contact PSIRThigh

Published

4 November 2026

Last update

4 November 2026

Affected sectors

Risk evaluation

GSDX SignatureValue verification, signed plug-in validation bypass and path traversal vulnerabilities have been identified in PLCnext Engineer prior to version 2026.6. The effects of these vulnerabilities may result in a complete loss of confidentiality, integrity and availability.

Mitigation summary

Phoenix Contact strongly recommends to upgrade to PLCnext Engineer 2026.6 which fixes these vulnerabilities.

Revision history (1)
  1. Initial publication — 14 October 2026

    Initial revision.

Official source: Phoenix Contact PSIRT

4JNO000550-1189

Node2Shell Vulnerability for Advanced Batch Management

ABB — Advanced Batch Management (ABM)

ABB PSIRThigh

Published

4 November 2026

Last update

4 November 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the product to stop, disclose process memory or insert and run arbitrary code.

Mitigation summary

The problem is corrected by updating the Node.js runtime used by the product versions listed as affected. A new ABM release containing the patched runtime is not yet available; until then, the runtime must be updated manually: - Node.js 24.x (ABM 1.2, 1.2.1): Update to Node.js 24.22.1 or later within the 24.x line. This version has been successfully tested with the ABM standard. ABB recommends that customers apply the update at earliest convenience. Major-version changes require compatibility testing before a production restart. Where ASP.NET Core / .NET components are deployed together with ABM, ABB additionally recommends installing the vendor-patched .NET releases.

Revision history (1)
  1. Initial publication — 4 November 2026

    Initial version.

Official source: ABB PSIRT

VDE-2026-119

Welotec: Multiple vulnerabilities in TK routers

Welotec — Industrial Routers

Welotec PSIRThigh

Published

3 November 2026

Last update

3 November 2026

Affected sectors

Risk evaluation

Multiple vulnerabilities in the web-based management functions of the affected Welotec routers, including VPN-related functions, may allow a remote attacker with high privileges to inject commands or trigger a buffer overflow. Successful exploitation may result in command execution with root privileges or a denial of service.

Mitigation summary

Do not expose the management interface to the internet or other untrusted networks. Restrict management access to trusted administrator workstations using network segmentation and firewall rules.

Revision history (1)
  1. Initial publication — 3 November 2026

    Initial release.

Official source: Welotec PSIRT

SA26P015

APROL Impact of PHP2Shell

B&R Industrial Automation GmbH — APROL

ABB PSIRTcritical

Published

23 October 2026

Last update

3 November 2026

Affected sectors

Risk evaluation

B&R is aware of public reports of a vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploits these vulnerabilities may insert and run arbitrary code on affected devices.

Mitigation summary

The problem is corrected in the following product versions: - version line R4.4-01: APROL-AutoYaST-DVD-V4.4-010.12.261023-SLE15-SP6 - version line R4.4-65: APROL-AutoYaST-DVD-V4.4-650.4.261022-SLE15-SP7 B&R recommends that customers apply the update at earliest convenience. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.

Revision history (2)
  1. Initial publication — 3 November 2026

    Affected products, recommended actions

  2. Update A — 23 October 2026

    Initial version.

Official source: ABB PSIRT

2NGA003224

PHP2Shell Critical Vulnerabilities

ABB — ARG600A1220NA

ABB PSIRTcritical

Published

30 October 2026

Last update

30 October 2026

Affected sectors

Risk evaluation

ABB is aware of publicly reported information concerning recently disclosed PHP vulnerabilities that impact the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability may insert and run arbitrary code on affected products. As part of ABB product lifecycle policy, once a product transitions to obsolete state, we discontinue maintenance, security patches, and technical support to focus on current and future technologies. While the product will continue to function, we strongly recommend implementing the mitigations de-fined in this document to reduce security risks.

Mitigation summary

Mitigating factors describe conditions and circumstances that make an attack that exploits vulnerability difficult or less likely to succeed. - Obtain a private cellular Access Point (private APN). A dedicated private APN and the corresponding SIM card subscriptions can be obtained from your cellular service provider. This service does not expose traffic between remote sites and the main site to the Internet. Instead, communication is carried over the cellular operator’s private wide area network (WAN). Therefore, the ARM600 does not require any inbound ports to be exposed to the Internet. - Avoid exposing any system component directly to the Internet. If the ARM600 must be exposed to the Internet, only the VPN port should be accessible from the Internet. Patrol management connections can be configured to use a VPN tunnel, and remote administration can be performed using an PC OpenVPN client or another VPN solution that provides mutual authentication. - Establish Demilitarized Zone (DMZ) architecture, where the ARM600 server is deployed in the DMZ to terminate VPN connections from remote sites. The DMZ must be segregated from other networks by a firewall. - Configure the device firewall according to the allowlisting principle (i.e., explicitly allow only the required ports and protocols and block all other traffic). - Change the default user credentials of the ARM600 and Arctic wireless gateways, and use strong, non-guessable passwords that include special characters. Do not reuse passwords within the system.

Revision history (1)
  1. Initial publication — 30 October 2026

    Initial version.

Official source: ABB PSIRT

SSA-898633

SSA-898633: Node2Shell Vulnerability in Palo Alto Networks PAN-OS on RUGGEDCOM APE1808 Devices

Siemens — RUGGEDCOM APE1808

Siemens ProductCERTcritical

Published

30 October 2026

Last update

30 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Palo Alto Networks has published [1] information on a vulnerability in PAN-OS related to the Node2Shell vulnerability. This advisory lists the related Siemens Industrial products affected by this vulnerability. Customers are advised to consult and implement the workarounds provided in Palo Alto Networks' upstream security notifications. [1] https://security.paloaltonetworks.com/CVE-2026-111497

Mitigation summary

Upgrade to corresponding available PAN-OS version. Contact customer support to receive additional patch and update information.

Revision history (1)
  1. Initial publication — 30 October 2026

    Publication Date

Official source: Siemens ProductCERT

VDE-2026-127

Welotec: PHP2Shell Vulnerabilities in SMART EMS

Welotec — SmartEMS

Welotec PSIRTcritical

Published

29 October 2026

Last update

29 October 2026

Affected sectors

Risk evaluation

Two memory-safety vulnerabilities in the PHP runtime bundled with SMART EMS allow an unauthenticated remote attacker to execute arbitrary code in the context of the PHP web worker. All SMART EMS versions up to and including v3.5.3 are affected. Exploitability and reliability depend on the PHP server interface, configuration, application behaviour, and worker reuse.

Mitigation summary

Do not expose the SMART EMS Web UI directly to the internet or other untrusted networks. Restrict access to trusted administrator workstations through network segmentation, firewall rules, or a VPN. Where operationally possible, enforce `memory_limit=-1` administratively and restart all PHP workers. Use a container or cgroup memory limit as an availability boundary and enforce conservative request-size, input, multipart-part, header, and nesting limits at the frontend. If multipart form data is not required, block such requests before they reach PHP. These measures reduce exposure to confirmed attack paths but are not a complete mitigation.

Revision history (1)
  1. Initial publication — 29 October 2026

    Initial release.

Official source: Welotec PSIRT

9AKK108473A4963

ASPECT advisory PHP Vulnerabilities

ABB — ASP-ENT-x

ABB PSIRTcritical

Published

29 October 2026

Last update

29 October 2026

Affected sectors

Risk evaluation

- General statement ABB became aware of vulnerabilities in ASPECT versions listed as affected in the advisory. The earliest report dates to Oct 2026. An attacker who successfully exploits these vulnerabilities may insert and run arbitrary code on affected products. ABB is currently investigating this vulnerability to provide adequate protection to customers. ASPECT is an on-premises Building Management System (BMS) that provides an additional option to be remotely accessible. - Statement on newly reported vulnerabilities ASPECT devices are not intended to be internet-facing. A product advisory issued in June 2023 informed customers regarding this fact. An attacker who successfully exploits these vulnerabilities could potentially gain unauthorized access and potentially compromise the system's - and log-file-confidentiality, integrity and availability. ABB requires, as noted in previous security advisories and user documentation, that ASPECT should not be exposed to the Internet or any other unsecured network. Note: To exploit ASPECT, an attacker would need a misconfigured system. ABB strongly advises customers and system integrators to follow the instructions documented in: FBXi, CBXi and ASPECT® SOLUTIONS, which can be downloaded from the ABB library.

Mitigation summary

Please immediately do the following actions on any released SW version of ASPECT: - Stop and disconnect any ASPECT products that are exposed directly to the Internet, either via a direct ISP connection or via NAT port forwarding - Ensure that physical controls are in place, so no unauthorized personnel can access your devices, components, peripheral equipment, and networks - Ensure log-files, downloaded from the equipment is protected against unauthorized access - Ensure that all ASPECT products are upgraded to the latest firmware version. Please find the latest version of ASPECT firmware on the respective product homepage - When remote access is required, only use secure methods. If a Virtual Private Network (VPN) is used, ensure that the chosen VPN is secure i.e. updated to the most current version available and configured for secure access

Revision history (1)
  1. Initial publication — 29 October 2026

    Initial version.

Official source: ABB PSIRT

SSA-137528

SSA-137528: Authentication Bypass Vulnerability in Mendix SAML module

Siemens — Mendix SAML (Mendix 10 compatible)

Siemens ProductCERTmiddel

Published

26 October 2026

Last update

26 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Mendix SAML module contains an authentication bypass vulnerability that could allow an unauthenticated remote attacker to gain unauthorized access by replaying a valid SAML assertion in IdP-initiated authentication flows. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Disable IdP-initiated SSO

Revision history (1)
  1. Initial publication — 26 October 2026

    Publication Date

Official source: Siemens ProductCERT

SSA-887643

SSA-887643: Account Hijacking Vulnerability in Mendix SAML module

Siemens — Mendix SAML (Mendix 10 compatible)

Siemens ProductCERThigh

Published

3 September 2026

Last update

26 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Mendix SAML module contains a vulnerability that could allow unauthenticated remote attackers to hijack an account in specific SSO configurations. Mendix has provided fix releases for the Mendix SAML module and recommends to update to the latest version.

Mitigation summary

Update to V3.6.29 or later version

Revision history (2)
  1. Initial publication — 3 September 2026

    Publication Date

  2. Update A — 26 October 2026

    Released new fixed versions, as the previous versions did not fully remediate the vulnerability.

Official source: Siemens ProductCERT

4hzk000017

ABB Manufacturing Execution System- PHP Vulnerabilities in DokuWiki installations

ABB — Manufacturing Execution System (MES)

ABB PSIRTcritical

Published

23 October 2026

Last update

23 October 2026

Affected sectors

Risk evaluation

ABB is aware of publicly reported vulnerabilities in the product listed as affected in the advisory. Updates to the affected component that fixed the vulnerabilities are available. An attacker who successfully exploited this vulnerability could remotely execute code on the server run-ning Dokuwiki. No active exploitations of the vulnerabilities have been reported by the time of writing this document

Mitigation summary

The vulnerabilities are not tight to any specific MES version but solely depend on the delivery including Dokuwiki, which relies on affected PHP versions. The affected PHP versions are listed in CERT-EU - Critical Vulnerabilities in PHP Reference section. The problem is corrected in the following product versions: • PHP 8.5.12 • PHP 8.4.27 • PHP 8.3.36 • PHP 8.2.35 ABB recommends that customers apply the updates immediately. The updates are applied by updating the PHP packages in operating system of the servers that run Dokuwiki. PHP 8.5.12, 8.4.27, 8.3.36 and 8.2.35 fix two critical vulnerabilities that can allow unauthenticated remote code execution. All PHP users are strongly encouraged to update immediately. PHP is installed on the web server / operating system, so upgrading PHP is a server administration task. It needs to be checked which PHP packages are installed on the system, and upgrade them (depending on the OS, with either ‘dnf’ or ‘yum’). ABB recommends that only PHP packages are updated, not the whole Dokuwiki installation.

Revision history (1)
  1. Initial publication — 23 October 2026

    Initial version.

Official source: ABB PSIRT

Advisory2026-12_VDE-2026-097

CODESYS Control Runtime - Improper Synchronization in Monitoring

CODESYS — CODESYS Control RTE (SL)

CODESYS PSIRThigh

Published

30 September 2026

Last update

22 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The monitoring functionality of affected CODESYS Control runtime systems processes read and write requests to PLC application data sent by the CODESYS Development System and other clients such as HMIs. Due to improper synchronization in the CmpMonitor2 component when processing concurrent requests from multiple clients, incorrect data may be read or written, potentially resulting in unexpected behavior of the affected product. PLCs based on the CODESYS Runtime Toolkit or CODESYS Safety SIL2 are affected if they allow simultaneous access by two or more clients via the CODESYS protocol. In CODESYS Development System 3, simultaneous access to the included Simulation Runtime can only occur when access by an external client, such as an HMI, has been explicitly enabled through dedicated configuration. The default configuration of CODESYS Development System 3 is not affected. The vulnerability can be exploited by an authenticated remote attacker with monitoring access by issuing concurrent requests to an affected product.

Mitigation summary

Update the following products to version 3.5.22.40. * CODESYS Control RTE (SL) * CODESYS Control RTE (for Beckhoff CX) SL * CODESYS Control Win (SL) * CODESYS Runtime Toolkit * CODESYS Safety SIL2 * CODESYS HMI (SL) * CODESYS Development System 3 The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.

Revision history (2)
  1. Initial publication — 30 September 2026

    Initial revision.

  2. Update A — 22 October 2026

    Updated remediation category - fixed SL runtimes are now available, formal adaptions.

Official source: CODESYS PSIRT

Advisory2026-11_VDE-2026-094

CODESYS Gateway Client - Uncontrolled Memory Allocation

CODESYS — CODESYS Development System 3

CODESYS PSIRThigh

Published

30 September 2026

Last update

22 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The CODESYS Gateway Client (CmpGwClient) is used by various CODESYS products to establish PLC communication via the CODESYS Gateway. Due to missing limits on memory allocations derived from a size field in a gateway response, a malicious gateway can cause excessive memory consumption in the client, resulting in a denial-of-service condition. The vulnerability can be exploited when an affected product connects to an attacker-controlled gateway.

Mitigation summary

Update the following products to version 3.5.22.40. * CODESYS Development System 3 * CODESYS Gateway * CODESYS Edge Gateway for Windows * CODESYS HMI (SL) * CODESYS OPC DA Server SL * CODESYS PLCHandler * CODESYS Runtime Toolkit The CODESYS Development System and the products available as CODESYS add-ons can be downloaded and installed directly with the CODESYS Installer or be downloaded from the CODESYS Store. Alternatively, as well as for all other products, you will find further information on obtaining the software update in the CODESYS Update area https://www.codesys.com/download/.

Revision history (2)
  1. Initial publication — 30 September 2026

    Initial revision.

  2. Update A — 22 October 2026

    Updated remediation category - fixed SL runtimes are now available, updated summary - typo corrected, formal adaptions.

Official source: CODESYS PSIRT

7PAA026271

ABB Ability Edgenius | Missing Authentication in Edgenius AuthDB

ABB — Ability Edgenius

ABB PSIRThigh

Published

22 October 2026

Last update

22 October 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB identified a critical vulnerability present in ABB Ability Edgenius versions 3.2.3.0 and below. We have not received any reports of this vulnerability being exploited. This issue may allow unauthorized manipulation of the edge authentication database if successfully exploited. ABB has developed and released a corrective update that resolves this vulnerability and enhances the security posture of the affected system.

Mitigation summary

Workarounds are specific measures that a user can take to help block an attack, for example, temporarily disabling the vulnerable feature may remove exposure with well-known impact on functionality. For brownfield customers, ABB provides a Kubernetes network policy that restricts access to Edge Authentication Database (AuthDB) to the authorized services required for normal operation of an already deployed and configured system. For implementation details, refer to Technical Description-ABB Ability Edgenius Missing Authentication in Edgenius AuthDB.docx (7PAA025722) listed in the reference section, distributed separately.

Revision history (1)
  1. Initial publication — 22 October 2026

    Initial version.

Official source: ABB PSIRT

FSA-202602

Multiple OpenSSL vulnerabilities affect Festo AX OS in CEPE

Festo — CEPE Product

Festo PSIRTcritical

Published

20 October 2026

Last update

20 October 2026

Affected sectors

Risk evaluation

Festo AX OS versions 25.0.1.46 and 25.9.2.4, which are based on PLCnext by Phoenix Contact, used by the Festo product CEPE are affected by multiple OpenSSL vulnerabilities. The vulnerabilities are identified as CVE-2025-15467 and CVE-2025-69419. Attacks may be possible when maliciously crafted firmware, key files, PKCS#12 files, CMS/PKCS#7 content, or digitally signed objects are uploaded and processed by the affected system. In the device context, exploitation typically requires a logged-in user with high privileges or the processing of attacker-supplied cryptographic objects.

Mitigation summary

Update affected CEPE installations running Festo AX OS 25.0.1.46 or Festo AX OS 25.9.2.4 to Festo AX OS 26.3.1.4 or later.

Revision history (1)
  1. Initial publication — 20 October 2026

    Initial Revision

Official source: Festo PSIRT

PPSA-2026-005

Pilz: Vulnerabilities in 'PiCtory' and 'RevPiPyLoad' for Industrial PC IndustrialPI

Pilz — IndustrialPI 4

Pilz PSIRThigh

Published

20 October 2026

Last update

20 October 2026

Affected sectors

Risk evaluation

The 'Pictory' web config tool, prior to 2.17.0, has a Cross-Site Request Forgery (CSRF) vulnerability, which makes it vulnerable to session takeover. The 'revpipyload' package, prior to version 0.11.1, has a vulnerability in the file management functionality of its XML-RPC interface. This allows an attacker to access or delete arbitrary files that the 'revpipyload' process has access to.

Mitigation summary

Update the 'pictory' package to version 2.17.0 or higher

Revision history (1)
  1. Initial publication — 20 October 2026

    Initial Version

Official source: Pilz PSIRT

PPSA-2026-004

Pilz: Vulnerabilities in 'piControl' kernel module for Industrial PC IndustrialPI

Pilz — IndustrialPI 4

Pilz PSIRThigh

Published

20 October 2026

Last update

20 October 2026

Affected sectors

Risk evaluation

The 'piControl' kernel module used in the IndustrialPI, prior to version 2.8.0-1, contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can lead to kernel memory corruption and denial of service.

Mitigation summary

Update package 'picontrol' to version 2.8.0-1 or higher.

Revision history (1)
  1. Initial publication — 20 October 2026

    Initial Version

Official source: Pilz PSIRT

SSA-580366

SSA-580366: DLL Sideloading Vulnerability in Siemens Software Center

Siemens — Siemens Software Center

Siemens ProductCERTmiddel

Published

15 October 2026

Last update

19 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The affected application loads dynamic-link libraries (DLLs) from an uncontrolled search path. This could allow an authenticated local attacker to place a specially crafted DLL in a directory that the application searches, leading to arbitrary code execution with the privileges of the affected application. Siemens has released a new version for Siemens Software Center and recommends to update to the latest version. Please refer to our blog post for additional information about current known active exploitation and how to detect it.

Mitigation summary

Update to V4.0.9.8 or later version (All existing versions of SSC will be auto updated on next startup. The latest version can also be downloaded in the respective link)

Revision history (3)
  1. Initial publication — 15 October 2026

    Publication Date

  2. Update A — 17 October 2026

    Added remediation for Siemens Software Center

  3. Update B — 19 October 2026

    Added reference to blog post about active exploitation of the vulnerability

Official source: Siemens ProductCERT

sca-2026-0016

Vulnerabilities Affecting SICK CorivaHub

SICK — Localization systems

SICK PSIRTcritical

Published

16 October 2026

Last update

16 October 2026

Affected sectors

Risk evaluation

SICK CorivaHub includes the third-party components Apache Tomcat and MapLibre GL, which are affected by two known vulnerabilities. These vulnerabilities include an improper input validation issue in Apache Tomcat and a vulnerability in MapLibre GL that could allow malicious behavior through custom GUIs. Under certain conditions, successful exploitation could affect the confidentiality, integrity and availability of the affected system. The attack surface associated with the Apache Tomcat vulnerability is significantly reduced by the default product configuration. Nevertheless, SICK recommends updating to CorivaHub 2026.1.2 to remediate both vulnerabilities.

Mitigation summary

Users are recommended to upgrade to version 2026.1.2.

Revision history (1)
  1. Initial publication — 16 October 2026

    Initial version

Official source: SICK PSIRT

sca-2026-0015

Vulnerability Affecting Sick_Safetyscanners_Base CPP Driver

SICK — Open Source Solutions

SICK PSIRThigh

Published

15 October 2026

Last update

15 October 2026

Linked CVEs

Affected sectors

Risk evaluation

An out-of-bounds read vulnerability exists in the open-source repository sick_safetyscanners_base (https://github.com/SICKAG/sick_safetyscanners_base), a standalone C++ driver library for SICK safety laser scanners. A specially crafted network packet could cause the library to read data beyond the bounds of the received buffer. If exploited, this vulnerability could potentially affect the availability of applications using the affected library. SICK recommends applying the defined remediations for this vulnerability.

Mitigation summary

Users are recommended to upgrade to version 1.0.5.

Revision history (1)
  1. Initial publication — 15 October 2026

    Initial version

Official source: SICK PSIRT

7PAA025438

My Control System 26.5 – Disk space exhaustion due to incorrect temporary file cleanup after XML conversion

ABB — My Control System

ABB PSIRTmiddel

Published

15 October 2026

Last update

15 October 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves a privately reported vulnerability to the product versions listed as affected in the advisory. An attacker who successfully exploited this vulnerability could cause the node running the product to stop or to become inaccessible.

Mitigation summary

Mitigating factors describe conditions and circumstances that make an attack that exploits the vulnerability difficult or less likely to succeed. Refer to section General security recommendations for further advice on how to keep your system secure. For the reported issue there are no known mitigating factors.

Revision history (1)
  1. Initial publication — 15 October 2026

    Initial version

Official source: ABB PSIRT