sca-2026-0014

Fast-xml-parser vulnerabilities affect Sentio Creator Extension 'Device Manager'

SICK — Engineering Tools

SICK PSIRTcritical

Published

14 October 2026

Last update

14 October 2026

Affected sectors

Risk evaluation

Multiple vulnerabilities in the third-party component fast-xml-parser affect the Device Manager Extension in Sentio Creator. The extension is maintained and updated independently from SICK Sentio Creator, but successful exploitation of these vulnerabilities could impact the security of the Sentio Creator. SICK strongly recommends upgrading the extension to remediate the identified issues.

Mitigation summary

It is strongly recommended to upgrade the Device Manger Extension to version 1.1.1.

Revision history (1)
  1. Initial publication — 14 October 2026

    Initial version

Official source: SICK PSIRT

VDE-2026-109

Bender Customer&Partner Platform Vulnerability - Privilege Escalation

Bender — Customer&Partner

Bender PSIRTmiddel

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Bender is publishing this advisory to inform customers about a security vulnerability in the Customer&Partner platform. The issue allows any account to view the roles of other users. Bender has analyzed the weakness and determined that user information and user credentials are not affected. Bender considers the weakness to be of medium risk which should be patched.

Mitigation summary

Bender service updated to version 5.17.5 or later. The fix is planned in Q4 2026.

Revision history (1)
  1. Initial publication — 13 October 2026

    initial version

Official source: Bender PSIRT

SEVD-2025-252-01

Multiple Altivar Process Drives and Communication Modules

Schneider Electric — ATVdPAC module

Schneider Electric CPCERTmiddel

Published

9 September 2025

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its [ATVdPAC module](http://www.se.com/ww/en/product/VW3A3530D/atv-dpac-module/) / [ATV6000 Medium Voltage Altivar Process Drives](http://www.se.com/ww/en/product-range/65607-altivar-process-atv6000) / [ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600) / [ATV930/950/955/960/980/9A0/9B0/9L0 Altivar Process Drives](http://www.se.com/ww/en/product-range/63124-altivar-process-atv900) / [ATV340E Altivar Machine Drives](http://www.se.com/ww/en/product-range/63441-altivar-machine-atv340#products) /[ATS490 Altivar Soft Starter](http://www.se.com/ww/en/product-range/213421154-altivar-soft-starter-ats490) / [Altivar Process Communication Modules](http://www.se.com/ww/en/product-range/62317-altivar-process-atv600/117623851529-modular-drives-apm) product(s). Failure to apply remediation mitigations provided below may risk Cross-Site Scripting, which could result in partial loss of confidentiality and integrity of the workstation running a Web browser.

Mitigation summary

Version 25.0 of VW3A3530D: ATVdPAC module includes a fix for this vulnerability and is available upon request from Schneider Electric's [Customer Care Center](https://www.se.com/us/en/work/support/contacts.jsp).

Revision history (4)
  1. Initial publication — 9 September 2025

    Original Release

  2. Update A — 16 September 2025

    Fixed the typo on the product name Altivar Process Communication Modules.

  3. Update B — 14 October 2025

    Remediations are now available for ATV630/650/660/680/6A0/6B0/6L0 Altivar Process Drives, ATV930/950/955/960/980/9A0/9B0/9L0/991/992/993 Altivar Process Drives and ATV340E Altivar Machine Drives.

  4. Update C — 9 December 2025

    Remediations are now available for ATS490 Altivar Soft Starter.

Official source: Schneider Electric CPCERT

SEVD-2026-286-01

Use of Unmaintained Third-Party Components vulnerability on Pro-face STW6000 and Harmony STW6

Schneider Electric — Pro-face STW6000

Schneider Electric CPCERThigh

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its Pro-face STW6000 and Harmony STW6 products. The Pro-face STW6000 and Harmony STW6 products are Basic Web HMI panels belongs to the Schneider Electric Harmony ST6 and Pro-face ST6000 range and is designed to meet the needs of simple machine operators for good visualization, connectivity, and cost-effective equipment. Failure to apply the mitigations provided below may risk various attack scenarios due to Third-party component obsolescence, which could result in unauthorized control to the device and operational failures.

Mitigation summary

Customers should immediately apply the following mitigations to reduce the risk of exploit: • Use HMI only in a protected environment to minimize network exposure and ensure that they are not accessible from public internet or untrusted networks. • Configure the trusted local websites for connecting and browsing in the HMI device. • Setup network segmentation and implement a firewall to block all unauthorized access. • Restrict usage of unverifiable portable media • Configuration must be done by a trusted administrator and authenticated users To ensure you are informed of all updates, including details on affected products and remediation plans, subscribe to Schneider Electric’s security notification service here: https://www.se.com/en/work/support/cybersecurity/security-notifications.jsp

Revision history (1)
  1. Initial publication — 13 October 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-286-02

SAGE RTU

Schneider Electric — Sage RTU

Schneider Electric CPCERThigh

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its SAGE RTU products. The SAGE RTU products are a line of devices designed for substation data acquisition and control. Failure to apply the mitigations provided below may enable a privileged user to install maliciously modified firmware on a SAGE RTU during an upgrade operation, resulting in modified device behavior.

Mitigation summary

Version C3414-500-S02L0 of SAGE RTU includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/download/document/C3414-500-S02L0_Firmware/ • Reboot needed: Yes After upgrading, navigate to the CPU configuration page to verify the firmware version number is correct.

Revision history (1)
  1. Initial publication — 13 October 2026

    Original Release

Official source: Schneider Electric CPCERT

SSA-019113

SSA-019113: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.6

Siemens — SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)

Siemens ProductCERTcritical

Risk evaluation

Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.6 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.6 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1.6 only; for version V3.1.7 refer to SSA-457936.

Mitigation summary

Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

Revision history (3)
  1. Initial publication — 14 July 2026

    Publication Date

  2. Update A — 8 September 2026

    Added 79 CVEs; Added fix for CVE-2026-43284, CVE-2026-46300 and CVE-2026-31431

  3. Update B — 13 October 2026

    Linked to V3.1.7

Official source: Siemens ProductCERT

SSA-055299

SSA-055299: Out-of-bounds Read Vulnerability in Capital Embedded AR Classic

Siemens — Capital Embedded AR Classic 431-422

Siemens ProductCERTmiddel

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The products listed below contain an out-of-bounds read vulnerability that could allow an attacker to cause abnormal product behavior, instability, or denial of service. Siemens has released a new version for Capital Embedded AR Classic R20-11 and recommends updating to the latest version. Siemens is preparing further fix versions and recommends specific countermeasures for products where fixes are not, or not yet available.

Mitigation summary

Apply network segmentation and put the ECUs behind properly configured gateways/firewalls

Revision history (1)
  1. Initial publication — 13 October 2026

    Publication Date

Official source: Siemens ProductCERT

SSA-082556

SSA-082556: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5

Siemens — SIMATIC S7-1500 CPU 1518-4 PN/DP MFP (6ES7518-4AX00-1AB0)

Siemens ProductCERTcritical

Risk evaluation

Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the firmware version V3.1.5 for the SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP (incl. SIPLUS variant). Siemens has released new versions for several affected products and recommends to update to the latest versions. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 CPU 1518(F)-4 PN/DP MFP V3.1.5 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V3.1.5 only; for version V3.1.6 refer to SSA-019113.

Mitigation summary

Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

Revision history (4)
  1. Initial publication — 10 June 2025

    Publication Date

  2. Update A — 12 August 2025

    Added CVE-2025-6395, CVE-2025-32988, CVE-2025-32989, CVE-2025-32990

  3. Update B — 13 January 2026

    Added CVE-2025-66382, CVE-2025-39929, CVE-2025-39931, CVE-2025-39977, CVE-2025-40022, CVE-2025-11082, CVE-2025-11083, CVE-2025-11412, CVE-2025-11413, CVE-2025-11414, CVE-2025-11494, CVE-2025-11495, CVE-2025-11839, CVE-2025-11840, CVE-2025-9230, CVE-2025-9232, CVE-2025-3198, CVE-2025-5244, CVE-2025-5245, CVE-2025-7545, CVE-2025-7546, CVE-2025-8224, CVE-2025-7425, CVE-2025-59375

  4. Update C — 10 February 2026

    Added 22 CVEs

Official source: Siemens ProductCERT

SSA-099819

SSA-099819: Denial of Service Vulnerability in SENTRON 3NA COM Fuse

Siemens — SENTRON 3NA COM Fuse

Siemens ProductCERTmiddel

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

SENTRON 3NA COM Fuse contains a Denial-of-Service vulnerability. Improper handling of a network management message could allow an attacker to trigger a denial-of-service (DoS) condition. Successful exploitation may require the affected network to be re-established to restore normal operation.

Mitigation summary

Update to V5.2 or later version

Revision history (1)
  1. Initial publication — 13 October 2026

    Publication Date

Official source: Siemens ProductCERT

SSA-148322

SSA-148322: WibuKey Denial of Service Vulnerability in PSS(R)SINCAL

Siemens — PSS(R)SINCAL V21.5

Siemens ProductCERThigh

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

PSS(R)SINCAL uses WibuKey third-party product that contains an out-of-bounds write vulnerability. An attacker could exploit this vulnerability to cause a system crash, resulting in a denial-of-service condition. This affects PSS SINCAL only when configured to use the legacy WibuKey dongle license type. Siemens is actively preparing updates and recommends applicable mitigations for products where patches are currently unavailable.

Mitigation summary

Install WIBU Systems WibuKey Runtime for Windows 6.72 or later version manually to fix the issue: Download the package from <a href="https://www.wibu.com/support/user/user-software.html">User Software - Wibu-Systems</a> and follow the installation instructions from WIBU Systems.

Revision history (1)
  1. Initial publication — 13 October 2026

    Publication Date

Official source: Siemens ProductCERT

SSA-159454

SSA-159454: Hard-coded Key Vulnerability in SIMATIC IPCs

Siemens — SIMATIC IPC BX-21A

Siemens ProductCERThigh

Published

13 October 2026

Last update

13 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The products listed below contain a vulnerability that could allow an attacker to boot an operating system or UEFI application signed with that test key, bypassing UEFI Secure Boot protections even when Secure Boot is enabled. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

<br/>Note: After upgrading to the fixed BIOS version, users must load the BIOS default settings. If Secure Boot keys were already provisioned, they must be provisioned again afterwards.

Revision history (1)
  1. Initial publication — 13 October 2026

    Publication Date

Official source: Siemens ProductCERT

SSA-265688

SSA-265688: Vulnerabilities in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1

Siemens — SIMATIC S7-1500 TM MFP - GNU/Linux subsystem

Siemens ProductCERTcritical

Risk evaluation

Multiple vulnerabilities have been identified in the additional GNU/Linux subsystem of the SIMATIC S7-1500 TM MFP V1.1. Siemens has released a new version for SIMATIC S7-1500 TM MFP - GNU/Linux subsystem and recommends to update to the latest version. Siemens is preparing further fixes and recommends specific mitigations for products where fixes are not or not yet available. SIMATIC S7-1500 TM MFP V1.1 is no longer maintained and there won't be any update to the CVE list anymore. Please update to the latest version. Note: This SSA advises vulnerabilities for firmware version V1.1 only; for version V1.1.1 refer to SSA-784472.

Mitigation summary

Limit access to the interactive shell of the additional GNU/Linux subssytem to trusted personnel only.

Revision history (4)
  1. Initial publication — 9 April 2024

    Publication Date

  2. Update A — 14 May 2024

    Added CVE-2024-2511

  3. Update B — 9 July 2024

    Added CVE-2024-5535

  4. Update C — 12 November 2024

    Added CVE-2024-9143

Official source: Siemens ProductCERT

VDE-2026-108

Murrelektronik: Missing Authentication in aas-edge-client Reference Implementation allows Manipulation of AAS Data

Murrelektronik — AAS Edge Client

Murrelektronik PSIRTcritical

Published

6 October 2026

Last update

6 October 2026

Linked CVEs

Affected sectors

Risk evaluation

The aas-edge-client is a reference implementation of an Asset Administration Shell (AAS) edge application, published by Murrelektronik GmbH on GitHub for the LNI 4.0 testbed demonstrator. Its REST API is bound to all network interfaces on TCP port 18000, requires no authentication and accepts cross-origin requests from any origin. The reference implementation was never intended for productive use and is no longer maintained. Affected are all aas-edge-client versions.

Mitigation summary

Discontinue the use of the aas-edge-client and remove any existing deployments as well as copies of the source code and container image. The code must not be used in any environment.

Revision history (1)
  1. Initial publication — 6 October 2026

    initial release

Official source: Murrelektronik PSIRT

VDE-2025-102

WAGO: Multiple Devices are affected by a Vulnerability in BACnet IP Stack

WAGO — CC100

WAGO PSIRTcritical

Published

1 October 2026

Last update

1 October 2026

Linked CVEs

Affected sectors

Risk evaluation

Multiple WAGO devices are affected by a vulnerability in the dynamic creation of BACnet File Objects. The object name is used as a file path without sufficient validation and is not restricted to the intended directory, so relative paths can be used to reach files elsewhere in the file system.

Mitigation summary

Update to Firmware version 4.8.9 (FW30) or higher. For the latest custom Firmware please contact the WAGO support.

Revision history (1)
  1. Initial publication — 1 October 2026

    Release version.

Official source: WAGO PSIRT

sca-2026-0011

Vulnerabilities in Wibu Systems CodeMeter Runtime Affect Multiple SICK Products

SICK — Industrial PCs

SICK PSIRThigh

Published

4 September 2026

Last update

30 September 2026

Affected sectors

Risk evaluation

Several vulnerabilities in the Wibu Systems CodeMeter Runtime affect the SICK products Sentio Creator, Sentio Compose, Safety Designer, Stream Editor, CODE-LOC, LiDAR-LOC, PLB, SIM1200-2A1A130 LiDAR-LOC and multiple SICK Industrial PCs (APU0G00, APU0G50, APU0G03, APU3F00, APU4600, APU8G00 and APU8G20), which ship with CodeMeter Runtime as part of their preinstalled image. For Sentio Compose, Safety Designer, Stream Editor and PLB, only CVE-2026-81572 is relevant. Vulnerabilities requiring the CodeMeter Runtime to be configured as a server are not applicable to default Sentio Compose, Safety Designer, Stream Editor and PLB installations, as the runtime is shipped with the Network Server and CmWAN Server functionalities disabled. Customers who have modified the default configuration and enabled CodeMeter server functionality should review the remaining vulnerabilities for potential impact. The vulnerabilities could potentially affect the integrity, confidentiality, and availability of the affected products.

Mitigation summary

Customers are strongy recommended to update the Codemeter Runtime to the latest version (>= 9.10). The software can be downloaded directly on the Wibu Systems website: https://www.wibu.com/de/support/anwendersoftware/anwendersoftware.html

Revision history (2)
  1. Initial publication — 4 September 2026

    Initial version

  2. Update A — 30 September 2026

    Added products LiDAR-LOC, CODE-LOC, and SIM1200-2A1A130 LiDAR-LOC. Updated the vendor fix information for Sentio Creator.

Official source: SICK PSIRT

9AKK108473A3188

Mint Workbench I Path traversal Vulnerability

ABB — Mint Workbench I

ABB PSIRThigh

Published

22 September 2026

Last update

29 September 2026

Linked CVEs

Affected sectors

Risk evaluation

A local attacker who successfully exploited this vulnerability could gain elevated privileges by Path Traversal, arbitrarily reading files of system, to cause confidentiality impact of system files.

Mitigation summary

Mint Workbench I 5876 and the versions before, are impacted, customers who use these products, should: - Disable Service MWI http when it is not in active use. - Restrict physical machine access to authorized personnel only. - Avoid storing sensitive or confidential data on any hosts running service MWI http. - Enable User Account Control (UAC) to block unauthorized privilege escalation attempts. These actions above are the only measures available. No further patch will be released because this product reaches end-of-life globally (out of China) by the end of 2026 and in China by the end of 2027. To exploit the vulnerability the attacker needs to have local access to the machine beforehand and have file write access in the path. Please also refer to section “General security recommendations” for further advise on how to keep your system secure.

Revision history (2)
  1. Initial publication — 29 September 2026

    MWI introduction

  2. Update A — 22 September 2026

    Initial version

Official source: ABB PSIRT

3ADR011566

ABB Automation Builder - Deserialization of untrusted data

ABB — Automation Builder

ABB PSIRThigh

Published

28 September 2026

Last update

28 September 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB is aware of vulnerabilities in the products versions listed as affected in the advisory. Automation Builder could execute arbitrary code by crafting the project file or project archive file.

Mitigation summary

The problem is corrected in the following product version: - Automation Builder 2.9.1 ABB recommends that customers apply the update at earliest convenience. Automation Builder 2.9.1 is available for download from the related download site.

Revision history (1)
  1. Initial publication — 28 September 2026

    Initial version.

Official source: ABB PSIRT

3ADR011565

AC500 V3 - Invalid type usage in visualization

ABB — AC500 V3 Firmware

ABB PSIRThigh

Published

28 September 2026

Last update

28 September 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves publicly reported vulnerability in the products versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could cause a denial-of-service (DoS).

Mitigation summary

The problem is corrected in the following product version: - AC500 V3 firmware version 3.9.1 ABB recommends that customers apply the update at earliest convenience. This firmware version is released for all AC500 V3 PLC types and integrated into Automation Builder 2.9.1. Automation Builder 2.9.1 is available for download from the related download site. https://www.abb.com/global/en/areas/motion/digital-tools/automation-builder/software-download

Revision history (1)
  1. Initial publication — 28 September 2026

    Initial version.

Official source: ABB PSIRT

2NGA003179

ABB Protection and Control IED Manager (PCM600) - PCM600 Project Import Path Traversal

ABB — Protection and control IED manager PCM600

ABB PSIRTmiddel

Published

28 September 2026

Last update

28 September 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB is aware of a privately reported vulnerability affecting the PCM600 project import functionality. An update is available that resolves this vulnerability in the affected product versions. A specially crafted PCM600 project archive may exploit insufficient validation of archive entry paths during project import. Successful exploitation could allow an attacker to create or overwrite files outside the intended extraction directory using the permissions of the importing user.

Mitigation summary

The problem is corrected in the following product version: - ABB Protection and Control IED Manager (PCM600) version 2.14 Hotfix 20260923. This fixed version is available through the ABB Update Manager and ABB website: PCM600 | ABB ABB recommends that customers upgrade to the available hotfix at the earliest opportunity. Until the update can be applied, customers should follow the mitigation measures described in this advisory.

Revision history (1)
  1. Initial publication — 28 September 2026

    Initial version.

Official source: ABB PSIRT

2NGA003170

ABB Protection and Control IED Manager PCM600 Scheduler Service Privilege Escalation Vulnerability

ABB — Protection and control IED manager PCM600

ABB PSIRTmiddel

Published

28 September 2026

Last update

28 September 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB is aware of a reported vulnerability in ABB Protection and Control IED Manager (PCM600). A local authenticated user belonging to the PCM600 user group may be able to modify the configuration of a Windows service running with SYSTEM privileges. Successful exploitation could allow an attacker to execute arbitrary commands with elevated privileges on the affected workstation. Note: This document references the ABBPCMSchedulerService_v214 component as implemented in PCM600 version 2.14. However, the described issue is not version-specific and applies equally to the corresponding component in other supported versions of PCM600.

Mitigation summary

ABB recommends the following workaround. Although this workaround does not correct the underlying vulnerability, it reduces the risk of privilege escalation. Configure the appropriate ABBPCMSchedulerService instance to run using the same Windows account that is used to operate PCM600. - Open Services.msc. - Locate the ABBPCMSchedulerService corresponding to the installed PCM600 version. - Open Properties and select the Log On tab. - The service should be configured to log on with the same Windows user account that is used for the PCM600 application. - Ensure that this account has the required "Log on as a service" privilege. When authentication is enabled for the IED, the Scheduler tool must be used with the same Windows account configured as the Scheduler Service logon account. For installations using IED security certificates, the PCM600 setting Always trust IED security certificates must be enabled only when PCM600-to-IED communication takes place in a secure and trusted environment. Impact of Workaround -Scheduler functionality will operate using the privileges of the configured Windows user account rather than SYSTEM privileges. - Users may need to be granted the "Log on as a service" Windows user right. - In environments using IED security certificates, enabling Always trust IED security certificates may reduce certificate validation protections and should only be used in secure and trusted environments. - Administrative effort may be required to maintain consistent user accounts between PCM600 and the Scheduler Service.

Revision history (1)
  1. Initial publication — 28 September 2026

    Initial version.

Official source: ABB PSIRT

ICSA-26-209-02

Siemens Mendix Runtime

Siemens — Mendix Runtime

CISAlow

Published

14 July 2026

Last update

24 September 2026

Linked CVEs

Affected sectors

Risk evaluation

This advisory is revoked. Re-investigation confirmed the reported behavior is expected platform configuration and does not expose the protected attribute.

Mitigation summary

See the official CISA advisory for mitigating measures.

Revision history (4)
  1. Initial publication — 14 July 2026

    Publication Date

  2. Update A — 28 July 2026

    CISA Republication - Initial CISA Republication of Siemens ProductCERT SSA-814963 advisory

  3. Update B — 22 September 2026

    Revoked advisory as the CVE is rejected

  4. Update C — 24 September 2026

    CISA Republication update based on Siemens ProductCERT SSA-814963 advisory

Official source: CISA

VDE-2026-089

Lenze: VPN Client Remote Code Execution in combination with Lenze x500 IoT Gateway

Lenze — VPN Client

Lenze PSIRTcritical

Published

21 September 2026

Last update

21 September 2026

Linked CVEs

Affected sectors

Risk evaluation

The Lenze VPN client is vulnerable to a Remote Code Execution. The vulnerability would allow an attacker to perform a remote code execution on the computer running the client with elevated privileges.

Mitigation summary

The Lenze VPN Client is available and downloadable via the Fleet Manager. Please update this Client. Obtain the update software (version >= 1.4.7) from https://cloud.lenze.digital/fleet-manager/tools and run the installer on a windows and macOS system or run the following commands in an linux system: ``` tar -xzf vpn_client_x64.tar.gz cd vpn_client_x64 sudo ./install ```

Revision history (1)
  1. Initial publication — 21 September 2026

    initial revision

Official source: Lenze PSIRT

7PAA010706

Freelance Missing Length Check

ABB — System Version

ABB PSIRThigh

Published

18 September 2026

Last update

18 September 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB is aware of a vulnerability in the product versions listed as affected in the advisory. An update is available that resolves the reported vulnerability in the product versions under maintenance. An attacker who successfully exploited this vulnerability could cause the product to stop or make the product inaccessible.

Mitigation summary

Refer to section “General security recommendations” for further advice on how to keep your system secure, as well checking the section “Workarounds”.

Revision history (1)
  1. Initial publication — 18 September 2026

    Initial version.

Official source: ABB PSIRT

4JDE002044

dynovaPRO™ Reset Credentials Vulnerability

ABB — dynovaPRO™ cloud system < 2026-08-27 12:00 (CEST)

ABB PSIRTcritical

Published

17 September 2026

Last update

17 September 2026

Linked CVEs

Affected sectors

Risk evaluation

ABB is aware of public reports of a vulnerability in the product listed as affected in the advisory. An update has been deployed to the cloud system that resolves a publicly reported vulnerability in the product versions listed above. An attacker who successfully exploited this vulnerability could take remote control of the product. The vulnerability has been identified in the keycloak authentication component which is integrated into dynovaPRO™. The vulnerability exists in the 'Forgot Password' functionality and allows unauthenticated attackers to bypass authentication and hijack user accounts. Users who have received a password reset mail before the mentioned date, without having requested it, are thereby potentially attacked by exploiting this vulnerability. ABB investigated potentially malicious user reset activities and blocked those user access immediately to reduce the exploitation risk. The credentials of those users have been deleted after the software fix was deployed and the users were informed that they must reset their password to gain access to dynovaPRO™ again.

Mitigation summary

The following conditions reduce the risk of exploitation of this vulnerability: - Limited Attack Surface: The vulnerability is specific to the password reset functionality. Other authentication methods are not affected. - Email Notifications: Legitimate users receive email notifications during password reset attempts, which may alert them to unauthorized access attempts. Refer to section “General security recommendations” for further advise on how to keep your system secure.

Revision history (1)
  1. Initial publication — 17 September 2026

    Initial version

Official source: ABB PSIRT

VDE-2026-027

Phoenix Contact: Multiple vulnerabilities in the firmware of IOL MA8 EIP DI8 and IOL MA8 PN DI8 devices

Phoenix Contact — IOL MA8 PN DI8

Phoenix Contact PSIRTcritical

Risk evaluation

The firmware of IOL MA8 EIP DI8 and IOL MA8 PN DI8 devices is affected by security vulnerabilities that can be used to bypass authentication. Code can be executed on the devices through command injection and local file inclusion. Path traversal and modified schemata can be used to read sensitive information such as password hashes or private keys from the devices.

Mitigation summary

Phoenix Contact strongly recommends to update affected devices to firmware version 1.7.8.

Revision history (1)
  1. Initial publication — 16 September 2026

    Initial release.

Official source: Phoenix Contact PSIRT