VDE-2026-014
Pepperl+Fuchs: ICE2-* and ICE3-* are affected by multiple security vulnerabilities
Published
16 September 2026
Last update
16 September 2026
Linked CVEs
Affected sectors
Risk evaluation
The affected devices have security vulnerabilities that can be used to bypass authentication. Code can be executed on the devices through command injection and local file inclusion. Path traversal and modified schemata can be used to read sensitive information such as password hashes or private keys from the devices.
Mitigation summary
Install update 1.7.8.
Revision history (1)
Initial publication — 16 September 2026
Initial release.
VDE-2026-091
TRUMPF: Multiple products affected by Wibu CodeMeter vulnerabilities
Published
15 September 2026
Last update
15 September 2026
Affected sectors
Risk evaluation
The TRUMPF product versions listed below include a Wibu CodeMeter Runtime version that contains several vulnerabilities, e.g. potentially allowing privilege escalation.
Mitigation summary
An updated Wibu Codemeter Runtime is available for download. If your installation is affected, the easiest fix is to install the latest Runtime from https://www.wibu.com/support/user/user-software.html
Revision history (1)
Initial publication — 15 September 2026
Initial version
Published
11 September 2026
Last update
11 September 2026
Linked CVEs
Affected sectors
Risk evaluation
SICK CorivaEngine includes the third-party components Netty and Spring Cloud Gateway that are affected by multiple known vulnerabilities. Under certain conditions, these vulnerabilities could allow remote attackers to perform HTTP request smuggling, cause resource exhaustion, or manipulate forwarded request headers. Successful exploitation may impact the integrity and availability of affected systems. SICK has addressed these vulnerabilities and recommends that customers apply the remediations described in this Security Advisory.
Mitigation summary
Users are recommended to upgrade to version 2026.1.1.
Revision history (1)
Initial publication — 11 September 2026
Initial version
3BHS973333
AC 800PEC, AC 800PEC ARM, AC 800PEC Tool, Control Terminal (xCT) and AC 800PEC Tool Cheetah Impacted by multiple vulnerabilities in Wibu CodeMeter
Published
10 September 2026
Last update
10 September 2026
Affected sectors
Risk evaluation
An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could - Allow arbitrary files to be deleted with system privileges (CVE-2026-81572), - Read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573) - Crash CodeMeter and disclose sensitive information such as process memory and stack canar-ies (CVE-2026-81574) - Crash CodeMeter (CVE-2026-81575), or - Read potentially sensitive license information (CVE-2026-81576)
Mitigation summary
For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.
Revision history (1)
Initial publication — 10 September 2026
Initial version.
2NGA003144
ABB AbilityTM zenon Security Risk Due to High-Severity Vulnerabilities in WIBU CodeMeter Runtime
Published
9 September 2026
Last update
9 September 2026
Affected sectors
Risk evaluation
ABB is aware of publicly disclosed security vulnerabilities affecting the WIBU-Systems CodeMeter Runtime for Windows, identified as CVE-2026-81572, CVE-2026-81573, CVE-2026-81574, CVE-2026-81575 and CVE-2026-81576. The CodeMeter Runtime component is used within affected ABB zenon Software Platform installations for software licensing and license server functionality. Successful exploitation of the reported vulnerabilities could enable local privilege escalation on Windows systems and impact systems configured as CodeMeter license servers, potentially leading to unauthorized access, service disruption, or loss of system integrity. Refer to the WIBU-Systems advisory for detailed technical information on each vulnerability. Please see the References section for the WIBU-Systems security advisory.
Mitigation summary
ABB recommends the following mitigation measures: - Update the WIBU-Systems CodeMeter Runtime to version 8.41a or later. - The latest CodeMeter Runtime software is available from the WIBU-Systems download page: User Software - Wibu-Systems, please see the References section for the corresponding link. - Where upgrading is not feasible, ABB recommends that asset owners perform a risk assessment and implement compensating controls such as network isolation, access restrictions, and enhanced monitoring of affected systems. ABB recommends that customers apply the update at earliest convenience. The vulnerabilities associated with CVE-2026-81573, CVE-2026-81574, CVE-2026-81575 and CVE-2026-81576 are exploitable only when the WIBU-Systems CodeMeter Runtime is configured as a network server, which is not the de-fault configuration. The CVE-2026-81572 vulnerability requires local access to the affected Windows system and execution by a low-privileged user. Consequently, systems with restricted local access, proper privilege management, and limited network exposure are less likely to be successfully compromised. Refer to section “General security recommendations” for further advise on how to keep your system secure.
Revision history (1)
Initial publication — 9 September 2026
Initial version.
Published
14 May 2019
Last update
8 September 2026
Linked CVEs
Affected sectors
Risk evaluation
Schneider Electric is aware of multiple vulnerabilities in its Modicon Controller products. The [Modicon Programmable Automation controllers](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/) are used for complex networked communication, display and control applications Failure to apply the mitigations or remediations provided below may risk execution of unsolicited command on the PLC which could result in a loss of availability of the controller.
Mitigation summary
Version sv4.20 of Modicon M580 includes a fix for this vulnerability and is available for download here: STEP 1: Update software and firmware. • On the engineering workstation, update to EcoStruxure Control Expert v16.0: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware • On the Modicon M580 controller, update to firmware SV4.20 or above: https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware STEP 2: Update projects in EcoStruxure™ Control Expert by: • Setting up an application password in the project properties • Changing the version of the controller firmware to match the new firmware version of the target controller STEP 3: Rebuild and transfer projects in EcoStruxure™ Control Expert: • Rebuild all current projects
Revision history (4)
Initial publication — 14 May 2019
Original Release
Update A — 9 July 2019
Updated to include links to M580 V2.90 Firmware and Control Expert Hot Fix v14.0
Update B — 12 July 2019
Updated mitigations for CVE-2019-6808
Update C — 24 July 2019
Updated links to M580 v2.90 Firmware
SEVD-2023-010-06
EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety
Risk evaluation
Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert, Modicon M340, Momentum, MC80, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability & safety solutions. The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. The Modicon MC80 provides optimized operation, withstanding extreme conditions with high reliability and performance. The Modicon Momentum supports control and distributed I/O system with 4 fundamental components that easily snap together in various combinations to form versatile control systems or sub-systems. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers). Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality and integrity of the controller.
Mitigation summary
Firmware SV4.20 includes a fix for this vulnerability and is available for download here:https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware
Revision history (4)
Initial publication — 10 January 2023
Original Release
Update A — 14 March 2023
Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7).
Update B — 8 August 2023
All versions of the EcoStruxure™ Process Expert are impacted by this vulnerability
Update C — 9 January 2024
A remediation is available for Modicon M580
SEVD-2024-044-01
EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 Safety PLCs
Schneider Electric — Modicon Momentum Unity M1E Processor Controller
Published
13 February 2024
Last update
8 September 2026
Linked CVEs
Affected sectors
Risk evaluation
Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert and Modicon M340, M580 PLCs (Programmable Logic Controllers). Modicon PLCs control and monitor industrial operations. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs. EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain an entire plant Infrastructure. Failure to apply the remediations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. Note regarding vulnerability details: The severity of vulnerabilities was calculated using the CVSS Base metrics in version 3.1 (CVSS v3.1) without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer’s environment
Mitigation summary
SV3.60 of Modicon M340 firmware includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/1468- modicon-m340
Revision history (4)
Initial publication — 13 February 2024
Original Release
Update A — 9 July 2024
Modicon MC80 and Momentum M1E PLCs have been identified as impacted by the CVE-2023-6408. Mitigations are now available
Update B — 13 August 2024
A remediation is available for the Modicon M580 CPU Safety (page 3).
Update C — 14 April 2026
Remediation is available for Modicon Momentum controller
SEVD-2024-317-02
Modicon Controllers M340 / Momentum / MC80 & EcoStruxure™ Control Expert
Published
12 November 2024
Last update
8 September 2026
Linked CVEs
Affected sectors
Risk evaluation
Schneider Electric is aware of multiple vulnerabilities in its Modicon Controllers M340 / Momentum / MC80 / EcoStruxure™ Control Expert products. [Modicon PAC](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/?filter=business-1-industrial-automation-and-control) products control and monitor industrial operations. [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview) is the engineering application for Modicon Controllers. Failure to apply the provided remediations/mitigations below may risk unauthorized access to the controller, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.
Mitigation summary
Firmware SV2.90 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/535-modicon-momentum/#software-and-firmware Important: Customer needs to use version of EcoStruxure™ Control Expert v16.2 HF003 minimum to connect with the latest version of Modicon Momentum.
Revision history (3)
Initial publication — 12 November 2024
Original Release
Update A — 14 April 2026
EcoStruxure™ Control Expert is added as affected offer and remediations are available for Modicon M340, EcoStruxure™ Control Expert, Modicon Momentum.
Update B — 8 September 2026
Remediation is available for Modicon MC80.
SEVD-2026-251-01
Multiple Vulnerabilities on EcoStruxure IT Data Center Expert
Published
8 September 2026
Last update
8 September 2026
Linked CVEs
Affected sectors
Risk evaluation
Schneider Electric is aware of its vulnerability in its EcoStruxure IT Data Center Expert product The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes,and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure and remote compromise of the offer which could result in disruption of operations and access to system data.
Mitigation summary
Version 9.2 of EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=61851#software-and-firmware Reboot needed: Upon installation, the service is automatically restarted. Users can validate a successful installation by logging in to the web client. The installed version is displayed in the bottom-left corner of the main screen.
Revision history (1)
Initial publication — 8 September 2026
Original Release
SEVD-2026-251-02
Improper Neutralization of Special Elements used in an OS Command vulnerability on PowerLogic T300
Risk evaluation
Schneider Electric is aware of a vulnerability in the Head Unit (HU250) for the PowerLogic T300 RTU (Remote Terminal Unit) (formerly Easergy T300 RTU). The [PowerLogic T300 RTU](https://www.se.com/ww/en/product-range/62399-easergy-t300) is a modular platform for medium voltage and low voltage public distribution network management. Failure to apply the remediation provided below may risk privilege escalation, which could result in unauthorized takeover of the device.
Mitigation summary
Version 2.9.8-5621 of PowerLogic T300 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to obtain the fixed firmware. • Reboot required
Revision history (1)
Initial publication — 8 September 2026
Original Release
SEVD-2026-251-04
Incorrect Implementation of Authentication Algorithm vulnerability on Modicon M580 and Modicon M580 Safety
Risk evaluation
Schneider Electric is aware of a vulnerability in its Modicon M580 and Modicon M580 Safety controllers. The Modicon M580 is an Ethernet-based Programmable Automation Controller (ePAC) designed for industrial digital transformation. Failure to apply the remediations provided below may risk establishing an unauthenticated connection to Modicon M580 or M580 Safety controllers which could result in loss of confidentiality, integrity and availability of the PLC.
Mitigation summary
Ensure to use firmware version 4.10 or above AND Update your application project to application level 4.00 or above. Application level 4.00 is available in EcoStruxure Control Expert V15.2 or later versions.
Revision history (1)
Initial publication — 8 September 2026
Original Release
SEVD-2026-251-03
Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products
Risk evaluation
Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality.
Mitigation summary
Implement the Role-Based Access Control (RBAC) feature and follow the SCADAPack documentation sections Security Guidelines for Administrators and Working with Role-Based Access Control. RBAC is the recommended access control mechanism for SCADAPack 47x devices and should be used in place of the Secure Lock feature. The Secure Lock feature is legacy functionality retained for backward compatibility with existing deployments and should only be used where required to support legacy system requirements. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, apply the following standard practices to reduce the risk of exploitation: • Configure network segmentation to restrict access between trusted and untrusted networks. • Enable and implement the RTU firewall service to restrict unauthorized access to device services and reduce the attack surface. Documentation available in [RemoteConnect and SCADAPack x70 Utilities | Schneider Electric](https://www.se.com/ww/en/download/document/RemoteConnect/)
Revision history (1)
Initial publication — 8 September 2026
Original Release
3ADR011572
Automation Builder, Drive Application Builder, Virtual Drive, Virtual DrivePlus Impacted by multiple vulnerabilities in Wibu CodeMeter
Published
3 September 2026
Last update
3 September 2026
Affected sectors
Risk evaluation
An update is available that resolves publicly reported vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could - allow arbitrary files to be deleted with system privileges (CVE-2026-81572), - read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573), - crash CodeMeter and disclose sensitive information such as process memory and stack canaries (CVE-2026-81574), - crash CodeMeter (CVE-2026-81575), or - read potentially sensitive license information (CVE-2026-81576)
Mitigation summary
For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts. For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.
Revision history (1)
Initial publication — 3 September 2026
Initial version.
SA26P012
mapp Services Use of Weak Authenticators in mapp Audit
Risk evaluation
An update is available that resolves a vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploits this vulnerability could gain access to the OPC UA server component on affected devices due to insufficient entropy of authenticators used by mapp Audit.
Mitigation summary
The problem is corrected in the following product versions: mapp Services >= 6.8.0 B&R recommends that customers apply the update at earliest convenience when the vulnerable functionality mapp Audit is used. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.
Revision history (1)
Initial publication — 3 September 2026
Initial version.
Published
21 July 2026
Last update
3 September 2026
Linked CVEs
Affected sectors
Risk evaluation
Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk.
Mitigation summary
Tycon Systems has released firmware 2.4.5, which resolves this vulnerability by requiring an administrator username and password to be set before the web interface is served. Further inquiries can be directed to security@tyconsystems.com.
Revision history (2)
Initial publication — 21 July 2026
Initial Publication
Update A — 3 September 2026
Updated affected version range and vulnerability details based on vendor input.
Risk evaluation
Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product.
Mitigation summary
Rockwell Automation recommends users are to migrate to 5034-OB8.
Revision history (2)
Initial publication — 21 July 2026
Initial Republication of Rockwell Automation Security Advisory
Update A — 1 September 2026
Update A - Updated impact statement and CVSS scores.
VDE-2026-061
Murrelektronik: Vulnerability in 'Copy learned MAC Addresses' function enables MAC Spoofing on Xelity Switches
Risk evaluation
An information disclosure vulnerability in the web GUI of Murrelektronik Xelity switches causes MAC addresses from the device's MAC address table to be written into a server-side log that is exposed via the device's web interface to unauthenticated users. The leak is triggered when an authenticated administrator invokes the 'Copy learned MAC Addresses' function, which causes a syslog error that inserts the affected MAC addresses into the log output. Once the error has been triggered, any unauthenticated attacker with network access to the web interface can retrieve the leaked MAC addresses via common browser developer tools. The vulnerable functionality was introduced in version 2.1.0 and is fixed in version 2.1.1.
Mitigation summary
Update the affected Xelity switches to firmware version V2.1.1 or later. This firmware version removes the syslog error that caused the MAC address table contents to be written to a web-accessible log.
Revision history (2)
Initial publication — 24 August 2026
initial release
Update A — 25 August 2026
The advisory title was edited. The vendor name was missing from the title.
VDE-2026-083
Weidmueller: Security routers IE-SR-2TX-WL and IE-SR-2TX-WL-4G are affected by multiple vulnerabilities
Published
25 August 2026
Last update
25 August 2026
Linked CVEs
Affected sectors
Risk evaluation
Weidmueller security routers IE-SR-2TX-WL and IE-SR-2TX-WL-4G are affected by an unauthenticated remote code execution vulnerability. IE-SR-2TX-WL-4G routers are also affected by a SMS password authorization bypass vulnerability. Weidmueller has released new firmware versions of the affected products to fix the vulnerabilities.
Mitigation summary
Restrict access to the web management interface using firewall rules, access control lists (ACLs), a VPN, or a trusted management network, and ensure the interface is not directly exposed to the public internet, until the firmware update is installed.
Revision history (1)
Initial publication — 25 August 2026
Initial version
SEVD-2026-132-02
Insufficient Entropy vulnerability on Multiple Products
Published
12 May 2026
Last update
25 August 2026
Linked CVEs
Affected sectors
, Transmissie, Distributie, Energieopwekking
Risk evaluation
Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. The Easergy MiCOM C264 is a modular and compact substation or bay controller, smart RTU and MV one box solution The EcoStruxure™ Power Automation System Gateway (EPAS=GTW) is a scalable, interoperable, and rugged communication gateway that helps to remotely monitor and operate electrical processes The EcoStruxure Power Automation System User Interface (EPAS-UI) product is an HMI SCADA designed for electrical networks and substations operations. The EcoStruxure Power Automation System Intelligent Power Management System and Fast Load Shedding (iPMFLS) is a range of solutions designed to overcome size and performances constraints. The EcoStruxure™ Power Operation (EPO) are an on-premises software offers that provides a single platform to monitor and control medium and lower power systems. The PowerLogic™ P5 is a medium voltage protection relay. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. The PowerLogic™ T300 is a modular platform for medium voltage and low voltage public distribution network management. The PowerLogicTM T500 is a control unit and RTU for substation automation. The Saitel DP RTU is a modular platform for medium voltage and low voltage public distribution and transmission network management. The EasyLogic T150 (formerly Saitel DR RTU) is a field device, offering a solid and powerful platform for data acquisition, communication, automation and IED integration for distribution and transmission networks, generation sector and railway. Failure to apply the fix provided below may risk session hijacking, which could result in malicious actors performing unauthorized operations within the affected system.
Mitigation summary
Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required
Revision history (2)
Initial publication — 12 May 2026
Original Release
Update A — 25 August 2026
Removed PowerChute Serial Shutdown as the product is not part of the Security Notification.
ICSA-26-232-01
Johnson Controls Simplex Incident Manager
Risk evaluation
Successful exploitation of this vulnerability could allow a local attacker with low privileges to extract user credentials (passwords and authentication tokens) from system memory, potentially leading to unauthorized access to the application and connected systems.
Mitigation summary
Johnson Controls has released a patched version (v2.01.01) to address this vulnerability. To help reduce the risk of exploitation, Johnson Controls suggests considering the following defensive measures: Upgrade the Simplex Incident Manager to version v1.01.05 or later. Restrict local access to systems running the Simplex Incident Manager to authorized personnel only. Implement endpoint protection and monitoring to detect memory-dumping tools or suspicious processes. Enforce strong access control policies and the principle of least privilege on host systems. Utilize full-disk encryption and secure boot to reduce the risk of offline memory analysis. Monitor for unauthorized local access attempts and implement audit logging.
Revision history (1)
Initial publication — 20 August 2026
Initial Republication of Johnson Controls Product Security Advisory JCI-PSA-2026-28
Risk evaluation
Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Mitigation summary
Update to V2606 or later version
Revision history (3)
Initial publication — 11 August 2026
Publication Date
Update A — 13 August 2026
Added Simcenter Femap with fix
Update B — 18 August 2026
Initial CISA Republication of Siemens ProductCERT SSA-069220 advisory
Risk evaluation
Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access.
Mitigation summary
Johnson Controls recommends the following actions:
Revision history (1)
Initial publication — 13 August 2026
Initial Publication.
Published
11 August 2026
Last update
13 August 2026
Linked CVEs
Affected sectors
Risk evaluation
Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive project logic and configurations. Siemens has released a new version for LOGO! Soft Comfort and recommends to update to the latest version.
Mitigation summary
Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present.
Revision history (2)
Initial publication — 11 August 2026
Publication Date
Update A — 13 August 2026
Initial CISA Republication of Siemens ProductCERT SSA-751328 advisory
Published
11 August 2026
Last update
13 August 2026
Linked CVEs
Affected sectors
Risk evaluation
Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions.
Mitigation summary
Update to V225.0 Update 15 or later version
Revision history (2)
Initial publication — 11 August 2026
Publication Date
Update A — 13 August 2026
Initial CISA Republication of Siemens ProductCERT SSA-621657 advisory