ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

499

Found

Advisory data: live connection— last retrieved: 20 November 2026 at 20:17.

Filters

499 advisories found

VDE-2026-014

Pepperl+Fuchs: ICE2-* and ICE3-* are affected by multiple security vulnerabilities

Pepperl+Fuchs — ICE2

Pepperl+Fuchs PSIRTcritical

Risk evaluation

The affected devices have security vulnerabilities that can be used to bypass authentication. Code can be executed on the devices through command injection and local file inclusion. Path traversal and modified schemata can be used to read sensitive information such as password hashes or private keys from the devices.

Mitigation summary

Install update 1.7.8.

Revision history (1)
  1. Initial publication — 16 September 2026

    Initial release.

Official source: Pepperl+Fuchs PSIRT

VDE-2026-091

TRUMPF: Multiple products affected by Wibu CodeMeter vulnerabilities

TRUMPF — CodeMeter User Runtime Kit for Windows 11

TRUMPF PSIRThigh

Published

15 September 2026

Last update

15 September 2026

Affected sectors

Risk evaluation

The TRUMPF product versions listed below include a Wibu CodeMeter Runtime version that contains several vulnerabilities, e.g. potentially allowing privilege escalation.

Mitigation summary

An updated Wibu Codemeter Runtime is available for download. If your installation is affected, the easiest fix is to install the latest Runtime from https://www.wibu.com/support/user/user-software.html

Revision history (1)
  1. Initial publication — 15 September 2026

    Initial version

Official source: TRUMPF PSIRT

sca-2026-0013

Vulnerabilities Affecting SICK CorivaEngine

SICK — Localization systems

SICK PSIRThigh

Published

11 September 2026

Last update

11 September 2026

Affected sectors

Risk evaluation

SICK CorivaEngine includes the third-party components Netty and Spring Cloud Gateway that are affected by multiple known vulnerabilities. Under certain conditions, these vulnerabilities could allow remote attackers to perform HTTP request smuggling, cause resource exhaustion, or manipulate forwarded request headers. Successful exploitation may impact the integrity and availability of affected systems. SICK has addressed these vulnerabilities and recommends that customers apply the remediations described in this Security Advisory.

Mitigation summary

Users are recommended to upgrade to version 2026.1.1.

Revision history (1)
  1. Initial publication — 11 September 2026

    Initial version

Official source: SICK PSIRT

3BHS973333

AC 800PEC, AC 800PEC ARM, AC 800PEC Tool, Control Terminal (xCT) and AC 800PEC Tool Cheetah Impacted by multiple vulnerabilities in Wibu CodeMeter

ABB — AC 800PEC

ABB PSIRThigh

Published

10 September 2026

Last update

10 September 2026

Affected sectors

Risk evaluation

An update is available that resolves a publicly reported vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could - Allow arbitrary files to be deleted with system privileges (CVE-2026-81572), - Read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573) - Crash CodeMeter and disclose sensitive information such as process memory and stack canar-ies (CVE-2026-81574) - Crash CodeMeter (CVE-2026-81575), or - Read potentially sensitive license information (CVE-2026-81576)

Mitigation summary

For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.

Revision history (1)
  1. Initial publication — 10 September 2026

    Initial version.

Official source: ABB PSIRT

2NGA003144

ABB AbilityTM zenon Security Risk Due to High-Severity Vulnerabilities in WIBU CodeMeter Runtime

ABB — AbilityTM zenon

ABB PSIRThigh

Published

9 September 2026

Last update

9 September 2026

Affected sectors

Risk evaluation

ABB is aware of publicly disclosed security vulnerabilities affecting the WIBU-Systems CodeMeter Runtime for Windows, identified as CVE-2026-81572, CVE-2026-81573, CVE-2026-81574, CVE-2026-81575 and CVE-2026-81576. The CodeMeter Runtime component is used within affected ABB zenon Software Platform installations for software licensing and license server functionality. Successful exploitation of the reported vulnerabilities could enable local privilege escalation on Windows systems and impact systems configured as CodeMeter license servers, potentially leading to unauthorized access, service disruption, or loss of system integrity. Refer to the WIBU-Systems advisory for detailed technical information on each vulnerability. Please see the References section for the WIBU-Systems security advisory.

Mitigation summary

ABB recommends the following mitigation measures: - Update the WIBU-Systems CodeMeter Runtime to version 8.41a or later. - The latest CodeMeter Runtime software is available from the WIBU-Systems download page: User Software - Wibu-Systems, please see the References section for the corresponding link. - Where upgrading is not feasible, ABB recommends that asset owners perform a risk assessment and implement compensating controls such as network isolation, access restrictions, and enhanced monitoring of affected systems. ABB recommends that customers apply the update at earliest convenience. The vulnerabilities associated with CVE-2026-81573, CVE-2026-81574, CVE-2026-81575 and CVE-2026-81576 are exploitable only when the WIBU-Systems CodeMeter Runtime is configured as a network server, which is not the de-fault configuration. The CVE-2026-81572 vulnerability requires local access to the affected Windows system and execution by a low-privileged user. Consequently, systems with restricted local access, proper privilege management, and limited network exposure are less likely to be successfully compromised. Refer to section “General security recommendations” for further advise on how to keep your system secure.

Revision history (1)
  1. Initial publication — 9 September 2026

    Initial version.

Official source: ABB PSIRT

SEVD-2019-134-11

Multiple Vulnerabilities in Modicon Controller Products

Schneider Electric — Modicon

Schneider Electric CPCERTcritical

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its Modicon Controller products. The [Modicon Programmable Automation controllers](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/) are used for complex networked communication, display and control applications Failure to apply the mitigations or remediations provided below may risk execution of unsolicited command on the PLC which could result in a loss of availability of the controller.

Mitigation summary

Version sv4.20 of Modicon M580 includes a fix for this vulnerability and is available for download here: STEP 1: Update software and firmware. • On the engineering workstation, update to EcoStruxure Control Expert v16.0: https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#software-and-firmware • On the Modicon M580 controller, update to firmware SV4.20 or above: https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware STEP 2: Update projects in EcoStruxure™ Control Expert by: • Setting up an application password in the project properties • Changing the version of the controller firmware to match the new firmware version of the target controller STEP 3: Rebuild and transfer projects in EcoStruxure™ Control Expert: • Rebuild all current projects

Revision history (4)
  1. Initial publication — 14 May 2019

    Original Release

  2. Update A — 9 July 2019

    Updated to include links to M580 V2.90 Firmware and Control Expert Hot Fix v14.0

  3. Update B — 12 July 2019

    Updated mitigations for CVE-2019-6808

  4. Update C — 24 July 2019

    Updated links to M580 v2.90 Firmware

Official source: Schneider Electric CPCERT

SEVD-2023-010-06

EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 CPU Safety

Schneider Electric — Modicon M340 CPU

Schneider Electric CPCERThigh

Published

10 January 2023

Last update

8 September 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert, Modicon M340, Momentum, MC80, M580 and M580 CPU Safety. The Modicon M580 are PAC and Safety PLCs with built-in Ethernet for process, high availability & safety solutions. The Modicon M340 offers compactness, flexibility, scalability, and robustness for the process industry and a wide range of demanding automation applications. The Modicon MC80 provides optimized operation, withstanding extreme conditions with high reliability and performance. The Modicon Momentum supports control and distributed I/O system with 4 fundamental components that easily snap together in various combinations to form versatile control systems or sub-systems. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs (Programmable Logic Controllers) and PACs (Programmable Automation Controllers). Failure to apply the mitigations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality and integrity of the controller.

Mitigation summary

Firmware SV4.20 includes a fix for this vulnerability and is available for download here:https://www.se.com/ww/en/product-range/62098-modicon-m580-epac/#software-and-firmware

Revision history (4)
  1. Initial publication — 10 January 2023

    Original Release

  2. Update A — 14 March 2023

    Modicon Momentum Unity M1E Process (page 6) and Modicon MC80 were added to the impacted products with the mitigations (page 7).

  3. Update B — 8 August 2023

    All versions of the EcoStruxure™ Process Expert are impacted by this vulnerability

  4. Update C — 9 January 2024

    A remediation is available for Modicon M580

Official source: Schneider Electric CPCERT

SEVD-2024-044-01

EcoStruxure™ Control Expert, EcoStruxure™ Process Expert and Modicon M340, M580 and M580 Safety PLCs

Schneider Electric — Modicon Momentum Unity M1E Processor Controller

Schneider Electric CPCERThigh

Published

13 February 2024

Last update

8 September 2026

Affected sectors

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its EcoStruxure™ Control Expert , EcoStruxure™ Process Expert and Modicon M340, M580 PLCs (Programmable Logic Controllers). Modicon PLCs control and monitor industrial operations. EcoStruxure™ Control Expert is the common programming, debugging and operating software for Modicon PLCs. EcoStruxure™ Process Expert DCS is a single automation system to engineer, operate, and maintain an entire plant Infrastructure. Failure to apply the remediations provided below may risk unauthorized access to your PLC, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller. Note regarding vulnerability details: The severity of vulnerabilities was calculated using the CVSS Base metrics in version 3.1 (CVSS v3.1) without incorporating the Temporal and Environmental metrics. Schneider Electric recommends that customers score the CVSS Environmental metrics, which are specific to end-user organizations, and consider factors such as the presence of mitigations in that environment. Environmental metrics may refine the relative severity posed by the vulnerabilities described in this document within a customer’s environment

Mitigation summary

SV3.60 of Modicon M340 firmware includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/1468- modicon-m340

Revision history (4)
  1. Initial publication — 13 February 2024

    Original Release

  2. Update A — 9 July 2024

    Modicon MC80 and Momentum M1E PLCs have been identified as impacted by the CVE-2023-6408. Mitigations are now available

  3. Update B — 13 August 2024

    A remediation is available for the Modicon M580 CPU Safety (page 3).

  4. Update C — 14 April 2026

    Remediation is available for Modicon Momentum controller

Official source: Schneider Electric CPCERT

SEVD-2024-317-02

Modicon Controllers M340 / Momentum / MC80 & EcoStruxure™ Control Expert

Schneider Electric — Modicon M340 CPU Controller

Schneider Electric CPCERThigh

Published

12 November 2024

Last update

8 September 2026

Affected sectors

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its Modicon Controllers M340 / Momentum / MC80 / EcoStruxure™ Control Expert products. [Modicon PAC](https://www.se.com/ww/en/product-subcategory/3950-pac-programmable-automation-controllers/?filter=business-1-industrial-automation-and-control) products control and monitor industrial operations. [EcoStruxure™ Control Expert](https://www.se.com/ww/en/product-range/548-ecostruxure-control-expert-unity-pro/#overview) is the engineering application for Modicon Controllers. Failure to apply the provided remediations/mitigations below may risk unauthorized access to the controller, which could result in the possibility of denial of service and loss of confidentiality, integrity of the controller.

Mitigation summary

Firmware SV2.90 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-range/535-modicon-momentum/#software-and-firmware Important: Customer needs to use version of EcoStruxure™ Control Expert v16.2 HF003 minimum to connect with the latest version of Modicon Momentum.

Revision history (3)
  1. Initial publication — 12 November 2024

    Original Release

  2. Update A — 14 April 2026

    EcoStruxure™ Control Expert is added as affected offer and remediations are available for Modicon M340, EcoStruxure™ Control Expert, Modicon Momentum.

  3. Update B — 8 September 2026

    Remediation is available for Modicon MC80.

Official source: Schneider Electric CPCERT

SEVD-2026-251-01

Multiple Vulnerabilities on EcoStruxure IT Data Center Expert

Schneider Electric — EcoStruxure IT Data Center Expert

Schneider Electric CPCERThigh

Published

8 September 2026

Last update

8 September 2026

Affected sectors

Risk evaluation

Schneider Electric is aware of its vulnerability in its EcoStruxure IT Data Center Expert product The EcoStruxure IT Data Center Expert product is a scalable monitoring software that collects, organizes,and distributes critical device information providing a comprehensive view of equipment. Failure to apply the remediation provided below may risk information disclosure and remote compromise of the offer which could result in disruption of operations and access to system data.

Mitigation summary

Version 9.2 of EcoStruxure™ IT Data Center Expert (Formerly known as StruxureWare Data Center Expert) includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product-country-selector/?pageType=product-range&sourceId=61851#software-and-firmware Reboot needed: Upon installation, the service is automatically restarted. Users can validate a successful installation by logging in to the web client. The installed version is displayed in the bottom-left corner of the main screen.

Revision history (1)
  1. Initial publication — 8 September 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-251-02

Improper Neutralization of Special Elements used in an OS Command vulnerability on PowerLogic T300

Schneider Electric — PowerLogic T300

Schneider Electric CPCERThigh

Published

8 September 2026

Last update

8 September 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in the Head Unit (HU250) for the PowerLogic T300 RTU (Remote Terminal Unit) (formerly Easergy T300 RTU). The [PowerLogic T300 RTU](https://www.se.com/ww/en/product-range/62399-easergy-t300) is a modular platform for medium voltage and low voltage public distribution network management. Failure to apply the remediation provided below may risk privilege escalation, which could result in unauthorized takeover of the device.

Mitigation summary

Version 2.9.8-5621 of PowerLogic T300 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center to obtain the fixed firmware. • Reboot required

Revision history (1)
  1. Initial publication — 8 September 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-251-04

Incorrect Implementation of Authentication Algorithm vulnerability on Modicon M580 and Modicon M580 Safety

Schneider Electric — Modicon

Schneider Electric CPCERTcritical

Published

8 September 2026

Last update

8 September 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Modicon M580 and Modicon M580 Safety controllers. The Modicon M580 is an Ethernet-based Programmable Automation Controller (ePAC) designed for industrial digital transformation. Failure to apply the remediations provided below may risk establishing an unauthenticated connection to Modicon M580 or M580 Safety controllers which could result in loss of confidentiality, integrity and availability of the PLC.

Mitigation summary

Ensure to use firmware version 4.10 or above AND Update your application project to application level 4.00 or above. Application level 4.00 is available in EcoStruxure Control Expert V15.2 or later versions.

Revision history (1)
  1. Initial publication — 8 September 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-251-03

Insufficiently Protected Credentials vulnerability on SCADAPack x70 Products

Schneider Electric — SCADAPack

Schneider Electric CPCERTmiddel

Published

8 September 2026

Last update

8 September 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its SCADAPack x70 products. The SCADAPack 47x, SCADAPack 47xi, SCADAPack 47xd, SCADAPack 470R and SCADAPack 57x products are Remote Terminal Units that provide communication capabilities for remote monitoring and control. Failure to apply the mitigations provided below may increase the risk of unauthorized access to RTU configuration through the Secure Lock functionality, potentially resulting in a loss of confidentiality.

Mitigation summary

Implement the Role-Based Access Control (RBAC) feature and follow the SCADAPack documentation sections Security Guidelines for Administrators and Working with Role-Based Access Control. RBAC is the recommended access control mechanism for SCADAPack 47x devices and should be used in place of the Secure Lock feature. The Secure Lock feature is legacy functionality retained for backward compatibility with existing deployments and should only be used where required to support legacy system requirements. Consult the SCADAPack Cybersecurity Guide, including the SCADAPack Hardening and Secured Communication sections. In addition, apply the following standard practices to reduce the risk of exploitation: • Configure network segmentation to restrict access between trusted and untrusted networks. • Enable and implement the RTU firewall service to restrict unauthorized access to device services and reduce the attack surface. Documentation available in [RemoteConnect and SCADAPack x70 Utilities | Schneider Electric](https://www.se.com/ww/en/download/document/RemoteConnect/)

Revision history (1)
  1. Initial publication — 8 September 2026

    Original Release

Official source: Schneider Electric CPCERT

3ADR011572

Automation Builder, Drive Application Builder, Virtual Drive, Virtual DrivePlus Impacted by multiple vulnerabilities in Wibu CodeMeter

ABB — Automation Builder

ABB PSIRThigh

Published

3 September 2026

Last update

3 September 2026

Affected sectors

Risk evaluation

An update is available that resolves publicly reported vulnerabilities in the product versions listed as affected in the advisory. An attacker who successfully exploited these vulnerabilities could - allow arbitrary files to be deleted with system privileges (CVE-2026-81572), - read potentially sensitive configuration data and overwrite selected values in Server.ini (CVE-2026-81573), - crash CodeMeter and disclose sensitive information such as process memory and stack canaries (CVE-2026-81574), - crash CodeMeter (CVE-2026-81575), or - read potentially sensitive license information (CVE-2026-81576)

Mitigation summary

For CVE-2026-81572 the exposure can be limited by auditing the list of local users and removing any unnecessary accounts. For CVE-2026-81573, CVE-2026-81574, CVE-2026-81575, and CVE-2026-81576: If you enabled the network server functionality at some point but no longer need it, disable it: - Open the Registry Editor and navigate to Computer\HKEY_LOCAL_MACHINE\SOFTWARE\ WIBUSYSTEMS\CodeMeter\Server\CurrentVersion\, then change the value of IsNetworkServerfrom 1 to 0. - Restart CodeMeter.

Revision history (1)
  1. Initial publication — 3 September 2026

    Initial version.

Official source: ABB PSIRT

SA26P012

mapp Services Use of Weak Authenticators in mapp Audit

B&R Industrial Automation GmbH — mapp Audit

ABB PSIRThigh

Published

3 September 2026

Last update

3 September 2026

Linked CVEs

Affected sectors

Risk evaluation

An update is available that resolves a vulnerability in the product versions listed as affected in the advisory. An attacker who successfully exploits this vulnerability could gain access to the OPC UA server component on affected devices due to insufficient entropy of authenticators used by mapp Audit.

Mitigation summary

The problem is corrected in the following product versions: mapp Services >= 6.8.0 B&R recommends that customers apply the update at earliest convenience when the vulnerable functionality mapp Audit is used. The process to install updates is described in the user manual. The step to identify the installed product version is described in the user manual.

Revision history (1)
  1. Initial publication — 3 September 2026

    Initial version.

Official source: ABB PSIRT

ICSA-26-202-01

Tycon Systems TPDIN-Monitor-WEB2 (Update A)

Tycon Systems — TPDIN-Monitor-WEB2

CISAcritical

Published

21 July 2026

Last update

3 September 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could result in an attacker accessing sensitive credentials, disrupting connected infrastructure, or manipulating physical equipment, which could present a physical safety risk.

Mitigation summary

Tycon Systems has released firmware 2.4.5, which resolves this vulnerability by requiring an administrator username and password to be set before the web interface is served. Further inquiries can be directed to security@tyconsystems.com.

Revision history (2)
  1. Initial publication — 21 July 2026

    Initial Publication

  2. Update A — 3 September 2026

    Updated affected version range and vulnerability details based on vendor input.

Official source: CISA

ICSA-26-202-09

Rockwell Automation 1734 POINT I/O (Update A)

Rockwell Automation — 1734 POINT I/O

CISAlow

Published

21 July 2026

Last update

1 September 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow for an attacker to cause a denial-of-service condition on the product.

Mitigation summary

Rockwell Automation recommends users are to migrate to 5034-OB8.

Revision history (2)
  1. Initial publication — 21 July 2026

    Initial Republication of Rockwell Automation Security Advisory

  2. Update A — 1 September 2026

    Update A - Updated impact statement and CVSS scores.

Official source: CISA

VDE-2026-061

Murrelektronik: Vulnerability in 'Copy learned MAC Addresses' function enables MAC Spoofing on Xelity Switches

Murrelektronik — Xelity

Murrelektronik PSIRTmiddel

Published

24 August 2026

Last update

25 August 2026

Linked CVEs

Affected sectors

Risk evaluation

An information disclosure vulnerability in the web GUI of Murrelektronik Xelity switches causes MAC addresses from the device's MAC address table to be written into a server-side log that is exposed via the device's web interface to unauthenticated users. The leak is triggered when an authenticated administrator invokes the 'Copy learned MAC Addresses' function, which causes a syslog error that inserts the affected MAC addresses into the log output. Once the error has been triggered, any unauthenticated attacker with network access to the web interface can retrieve the leaked MAC addresses via common browser developer tools. The vulnerable functionality was introduced in version 2.1.0 and is fixed in version 2.1.1.

Mitigation summary

Update the affected Xelity switches to firmware version V2.1.1 or later. This firmware version removes the syslog error that caused the MAC address table contents to be written to a web-accessible log.

Revision history (2)
  1. Initial publication — 24 August 2026

    initial release

  2. Update A — 25 August 2026

    The advisory title was edited. The vendor name was missing from the title.

Official source: Murrelektronik PSIRT

VDE-2026-083

Weidmueller: Security routers IE-SR-2TX-WL and IE-SR-2TX-WL-4G are affected by multiple vulnerabilities

Weidmüller — IE-SR

Weidmüller PSIRTcritical

Published

25 August 2026

Last update

25 August 2026

Affected sectors

Risk evaluation

Weidmueller security routers IE-SR-2TX-WL and IE-SR-2TX-WL-4G are affected by an unauthenticated remote code execution vulnerability. IE-SR-2TX-WL-4G routers are also affected by a SMS password authorization bypass vulnerability. Weidmueller has released new firmware versions of the affected products to fix the vulnerabilities.

Mitigation summary

Restrict access to the web management interface using firewall rules, access control lists (ACLs), a VPN, or a trusted management network, and ensure the interface is not directly exposed to the public internet, until the firmware update is installed.

Revision history (1)
  1. Initial publication — 25 August 2026

    Initial version

Official source: Weidmüller PSIRT

SEVD-2026-132-02

Insufficient Entropy vulnerability on Multiple Products

Schneider Electric — EasyLogic T150 (formerly Saitel DR)

Schneider Electric CPCERThigh

Published

12 May 2026

Last update

25 August 2026

Linked CVEs

Affected sectors

, Transmissie, Distributie, Energieopwekking

Risk evaluation

Schneider Electric is aware of a vulnerability in the following products: The Easergy C5 is a scalable and interoperable bay controller, protection and merging unit for large and critical infrastructure electrical distribution systems. The Easergy MiCOM P30 is a family of multifunction protection and control relays designed for medium, high and extra high voltage electrical networks. The Easergy MiCOM P40 is a protection relay series for Medium Voltage, High Voltage and Extra High Voltage protection. The Easergy MiCOM C264 is a modular and compact substation or bay controller, smart RTU and MV one box solution The EcoStruxure™ Power Automation System Gateway (EPAS=GTW) is a scalable, interoperable, and rugged communication gateway that helps to remotely monitor and operate electrical processes The EcoStruxure Power Automation System User Interface (EPAS-UI) product is an HMI SCADA designed for electrical networks and substations operations. The EcoStruxure Power Automation System Intelligent Power Management System and Fast Load Shedding (iPMFLS) is a range of solutions designed to overcome size and performances constraints. The EcoStruxure™ Power Operation (EPO) are an on-premises software offers that provides a single platform to monitor and control medium and lower power systems. The PowerLogic™ P5 is a medium voltage protection relay. The PowerLogic™ P7 is a protection and control platform designed for complex and advanced electrical network applications. The PowerLogic™ T300 is a modular platform for medium voltage and low voltage public distribution network management. The PowerLogicTM T500 is a control unit and RTU for substation automation. The Saitel DP RTU is a modular platform for medium voltage and low voltage public distribution and transmission network management. The EasyLogic T150 (formerly Saitel DR RTU) is a field device, offering a solid and powerful platform for data acquisition, communication, automation and IED integration for distribution and transmission networks, generation sector and railway. Failure to apply the fix provided below may risk session hijacking, which could result in malicious actors performing unauthorized operations within the affected system.

Mitigation summary

Version D7.34 of MiCOM C264 includes a fix for this vulnerability. Contact Schneider Electric’s Customer Care Center for information on how to contact your local Application Center to update the device. Reboot is required

Revision history (2)
  1. Initial publication — 12 May 2026

    Original Release

  2. Update A — 25 August 2026

    Removed PowerChute Serial Shutdown as the product is not part of the Security Notification.

Official source: Schneider Electric CPCERT

ICSA-26-232-01

Johnson Controls Simplex Incident Manager

Johnson Controls Inc. — Simplex Incident Manager

CISAmiddel

Published

20 August 2026

Last update

20 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow a local attacker with low privileges to extract user credentials (passwords and authentication tokens) from system memory, potentially leading to unauthorized access to the application and connected systems.

Mitigation summary

Johnson Controls has released a patched version (v2.01.01) to address this vulnerability. To help reduce the risk of exploitation, Johnson Controls suggests considering the following defensive measures: Upgrade the Simplex Incident Manager to version v1.01.05 or later. Restrict local access to systems running the Simplex Incident Manager to authorized personnel only. Implement endpoint protection and monitoring to detect memory-dumping tools or suspicious processes. Enforce strong access control policies and the principle of least privilege on host systems. Utilize full-disk encryption and secure boot to reduce the risk of offline memory analysis. Monitor for unauthorized local access attempts and implement audit logging.

Revision history (1)
  1. Initial publication — 20 August 2026

    Initial Republication of Johnson Controls Product Security Advisory JCI-PSA-2026-28

Official source: CISA

ICSA-26-230-02

Siemens Simcenter Nastran

Siemens — Simcenter Femap

CISAhigh

Published

11 August 2026

Last update

18 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Simcenter Nastran is affected by a stack overflow vulnerability that could be triggered when an application binary reads arbitrary string as a file argument. If a user is tricked to run one of the impacted application binary with a malicious string, an attacker could leverage the vulnerability to perform remote code execution in the context of the current process. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Update to V2606 or later version

Revision history (3)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Added Simcenter Femap with fix

  3. Update B — 18 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-069220 advisory

Official source: CISA

ICSA-26-225-14

Johnson Controls Metasys

Johnson Controls Inc. — Metasys 12

CISAhigh

Published

13 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow a low-privilege user or attacker to inject a persistent malicious payload via a crafted URL that executes in the context of other users' sessions, including administrators, potentially leading to session hijacking and unauthorized access.

Mitigation summary

Johnson Controls recommends the following actions:

Revision history (1)
  1. Initial publication — 13 August 2026

    Initial Publication.

Official source: CISA

ICSA-26-225-13

Siemens LOGO! Soft Comfort

Siemens — LOGO! Soft Comfort

CISAmiddel

Published

11 August 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Siemens LOGO! Soft Comfort contains multiple vulnerabilities in its project-file encryption and password handling mechanisms. A local attacker could exploit these vulnerabilities to extract the master key, allowing them to decrypt project data or remove project passwords. The lack of password salting enables offline dictionary or brute-force attacks against the password hashes. Successful exploitation could result in unauthorized access to, or modification of, sensitive project logic and configurations. Siemens has released a new version for LOGO! Soft Comfort and recommends to update to the latest version.

Mitigation summary

Update to V9 or later version Note: A hardware upgrade to LOGO! V9 BM or later is also required to avoid compatibility mode, in which the vulnerabilities addressed by this advisory remain present.

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-751328 advisory

Official source: CISA

ICSA-26-225-12

Siemens Solid Edge

Siemens — Solid Edge SE2025

CISAhigh

Published

11 August 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Solid Edge is affected by multiple file parsing vulnerabilities that could be triggered when the application reads specially crafted files in PAR, PSM or DFT format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Update to V225.0 Update 15 or later version

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-621657 advisory

Official source: CISA