Skip to content
IACS RadarIndustrial Cyber Exposure & Intelligence

CISA + vendors

ICS Advisories

Advisories specifically aimed at industrial control systems — from CISA ICS-CERT and directly from vendors (including Siemens, ABB, Schneider Electric, WAGO and Phoenix Contact) — including revision history (initial publication, Update A, Update B) and linked CVEs.

499

Found

Advisory data: live connection— last retrieved: 20 November 2026 at 20:48.

Filters

499 advisories found

ICSA-26-225-11

Siemens Simcenter Femap

Siemens — Simcenter Femap

CISAhigh

Published

11 August 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Simcenter Femap contains two file parsing vulnerabilities that could be triggered when the application reads files in BMP file format. If a user is tricked to open a malicious file with the affected application, this could lead the application to crash or potentially lead to arbitrary code execution. Siemens has released a new version for Simcenter Femap and recommends to update to the latest version.

Mitigation summary

Update to V2606.0001 or later version

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-584312 advisory

Official source: CISA

ICSA-26-225-10

Siemens Parasolid

Siemens — Parasolid V38.0

CISAhigh

Published

11 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Parasolid is affected by an out of bounds read vulnerability that could be triggered when the application reads files in X_T format. This could allow an attacker to crash the application or execute arbitrary code. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Update to V38.0.235 or later version

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-138516 advisory

Official source: CISA

ICSA-26-225-09

Siemens Siveillance Video

Siemens — Siveillance Video V2023 R3

CISAcritical

Published

11 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Siveillance Video Management Servers contains a vulnerability that could allow a Remote Code Execution attack. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Update to V23.3 HotfixRev27 or later version

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens SSA-825228 advisory

Official source: CISA

ICSA-26-225-08

Siemens Desigo DXR and PXC Controllers

Siemens — Desigo DXR2

CISAmiddel

Published

11 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in Desigo DXR and PXC controllers has been identified that could allow an attacker to cause denial of service conditions by sending malformed BACnet packets. Recovery requires a device reset or reboot to restore normal functionality. Siemens has released new versions for the affected products and recommends to update to the latest versions.

Mitigation summary

Update to V01.21.233.16-7862 or later version Please contact your local Siemens office for additional support in obtaining the update.

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 13 August 2026

    Initial CISA Republication of Siemens SSA-781903 advisory

Official source: CISA

ICSA-26-225-05

ANDRITZ HIPASE-250 and 250 SCALA

ANDRITZ — HIPASE-250

CISAhigh

Published

13 August 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could allow an attacker to read data from the device or gain access to affected workstations.

Mitigation summary

ANDRITZ has addressed these issues in version V8.00.00 (released 2024-12) and in version V8.15.00 (released 2026-07) and encourages users to keep their systems updated to the latest version (currently HIPASE-250 Version V8.15.00). For more information, users can contact ANDRITZ at the following website: https://www.andritz.com/group-en/contact

Revision history (1)
  1. Initial publication — 13 August 2026

    Initial Publication

Official source: CISA

ICSA-26-225-04

Hitachi Energy APM Edge Product

Hitachi Energy — APM Edge

CISAhigh

Published

28 July 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Hitachi Energy is aware of Dirty Frag vulnerabilities that affect APM Edge product versions listed in this document. Successful exploitation of these vulnerabilities could result in impact on confidentiality, integrity and availability of the product. Please refer to the Recommended Immediate Actions for information about the mitigation/remediation.

Mitigation summary

Disable the esp4 and esp6 modules [2]

Revision history (2)
  1. Initial publication — 28 July 2026

    Initial public release

  2. Update A — 13 August 2026

    Initial CISA Republication of Hitachi Energy PSIRT 8DBD000256 advisory

Official source: CISA

ICSA-26-225-03

Johnson Controls Inc. Airwall

Johnson Controls Inc. — Airwall

CISAmiddel

Published

13 August 2026

Last update

13 August 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could allow an attacker to decrypt sensitive data, bypass authentication controls, gaining unauthorized access to read arbitrary files on the system, or gain unauthorized access to protected system resources.

Mitigation summary

To help reduce risk of exploitation, Johnson Controls recommends the following defensive measures: Apply v4.1.0 or later patches for all Airwalls.

Revision history (1)
  1. Initial publication — 13 August 2026

    Initial Republication of Johnson Controls JCI-PSA-2026-18 and JCI-PSA-2026-25

Official source: CISA

ICSA-26-225-02

Haiwell IoT Cloud HMI Gateway

Haiwell — Haiwell IoT Cloud HMI Gateway

CISAcritical

Published

13 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability may allow an attacker to inject and execute arbitrary OS commands with root privileges.

Mitigation summary

Haiwell has addressed the issue in patch version number Scada-v3.50.1.19, which is available for download on their website: https://en.haiwell.com/app/system/entrance.php?m=include&c=access&a=dodown&lang=en&id=361

Revision history (1)
  1. Initial publication — 13 August 2026

    Initial Publication

Official source: CISA

ICSA-26-225-01

AVEVA Enterprise SCADA

AVEVA — Enterprise SCADA

CISAhigh

Published

13 August 2026

Last update

13 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow an attacker to tamper with serialized data, potentially resulting in code execution during deserialization.

Mitigation summary

AVEVA recommends that customers using affected product versions should perform the following to mitigate the risk of exploit: 1. Evaluate the impact of these vulnerabilities based on your operational environment, architecture, and product implementation. 2. Plan an upgrade of Servers and Clients to one of the available fixed versions listed in this document. 3. Configure Servers and Clients as described in this document.

Revision history (1)
  1. Initial publication — 13 August 2026

    Initial Republication of AVEVA security bulletin AVEVA-2026-005

Official source: CISA

vde-2025-056

Phoenix Contact: Improper Input Validation Vulnerabilities in PLCnext Firmware

Phoenix Contact — Catan C1

Phoenix Contact PSIRTcritical

Published

12 August 2026

Last update

12 August 2026

Affected sectors

Risk evaluation

This advisory addresses multiple security vulnerabilities in PLCnext firmware versions prior to 2026.0.3. The vulnerabilities may allow unauthenticated attackers to cause denial of service, trigger unexpected system behavior, or execute unauthorized SQL queries. Successful exploitation could impact the availability, integrity, and confidentiality of affected PLCnext Control devices. All issues are resolved in PLCnext firmware version 2026.0.3.

Mitigation summary

Update to PLCnext firmware version 2026.0.3 or later which fixes this vulnerability. Check regularly for firmware updates and apply them as soon as they are available for the specific device.

Revision history (1)
  1. Initial publication — 12 August 2026

    Initial

Official source: Phoenix Contact PSIRT

ICSA-26-225-07

Siemens License Server (SLS)

Siemens — Siemens License Server (SLS)

CISAhigh

Published

11 August 2026

Last update

12 August 2026

Affected sectors

Risk evaluation

Siemens License Server is affected by multiple vulnerabilities which could allow an attacker to elevate its privileges and read arbitrary files on the system. Siemens has released a new version for Siemens License Server (SLS) and recommends to update to the latest version.

Mitigation summary

Update to V5.1 or later version

Revision history (2)
  1. Initial publication — 11 August 2026

    Publication Date

  2. Update A — 12 August 2026

    Initial CISA Republication of Siemens ProductCERT SSA-077553 advisory

Official source: CISA

SEVD-2025-224-05

Modicon M340 Controller and Communication Modules

Schneider Electric — Modicon M340 Controller

Schneider Electric CPCERThigh

Published

12 August 2025

Last update

11 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of a vulnerability in its Modicon M340 https://www.se.com/ww/en/product-range/1468-modicon-m340-pac/, BMXNOR0200H https://www.se.com/us/en/product/BMXNOR0200H/communication-module-modicon-m340-iec-608705101-104-dnp3-for-severe-environments/: Modicon M340 X80 Ethernet Communication Modules, BMXNGD0100 https://www.se.com/us/en/product/BMXNGD0100/communication-module-modicon-m580-global-data-service/: M580 Global Data module, BMXNOC0401 https://www.se.com/us/en/product/BMXNOC0401/network-module-modicon-m340-ethernet-ip-and-modbus-tcp-4-x-rj45/?pageType=product&sourceId=BMXNOC0401: Modicon M340 X80 Ethernet Communication modules, BMXNOE0100 https://www.se.com/ww/en/product/BMXNOE0100/network-module-modicon-m340-modbus-tcp-1-x-rj45-flash-memory-card/?pageType=product&sourceId=BMXNOE0100: Modbus/TCP Ethernet Modicon M340 module, BMXNOE0110 https://www.se.com/ww/en/product/BMXNOE0110/ethernet-tcp-ip-network-module-modicon-m340-automation-platform-flash-memory-card-internal-ram-16-mb-1-x-rj45-10-100/: Modbus/TCP Ethernet Modicon M340 FactoryCast module product(s). Failure to apply the fix provided below may risk Denial Of Service attack, which could result in the unavailability of the devices.

Mitigation summary

Version 3.60 of BMXNOE0100 includes a fix for this vulnerability and is available for download here: https://www.se.com/ww/en/product/BMXNOE0100/networkmodule-modicon-m340-modbus-tcp-1-x-rj45-flash-memorycard/ Reboot is needed to complete the firmware upgrade

Revision history (3)
  1. Initial publication — 12 August 2025

    Original Release

  2. Update A — 14 April 2026

    Remediation is available for Modicon M340

  3. Update B — 11 August 2026

    Remediation is available for BMXNOR0200H.

Official source: Schneider Electric CPCERT

SEVD-2026-223-02

Multiple Vulnerabilities on NetBotz 5 750/755 Products

Schneider Electric — NetBotz 5 750

Schneider Electric CPCERTmiddel

Published

11 August 2026

Last update

11 August 2026

Affected sectors

Risk evaluation

Schneider Electric is aware of multiple vulnerabilities in its NetBotz 5 – 750/755 products.The NetBotz 5 – 750/755 products are security and environmental monitors providing temperature, humidity, leak, smoke, vibration, door contact, and video monitoring capabilities.Failure to apply the remediation provided below may risk arbitrary or remote code execution over the local network, which could result in device manipulation and unauthorized data access.

Mitigation summary

Version 5.6.0 of NetBotz 5 750/755 includes a fix for these vulnerabilities and is available for download here: https://www.se.com/us/en/product-range/61830-netbotz/#software-and-firmware Reboot needed: Upon install, the offer will automatically restart. A customer can validate a successful install by logging into the GUI and selecting the ‘About NetBotz’ option. This will indicate the installed version.

Revision history (1)
  1. Initial publication — 11 August 2026

    Original Release

Official source: Schneider Electric CPCERT

SEVD-2026-223-01

Improper Restriction of Excessive Authentication Attempts vulnerability on PowerChute Serial Shutdown

Schneider Electric — Microsoft Windows

Schneider Electric CPCERTmiddel

Published

11 August 2026

Last update

11 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Schneider Electric is aware of vulnerabilities in its PowerChute™ Serial Shutdown product. The PowerChute Serial Shutdown product is a UPS management software enabling graceful system shutdown and energy management capabilities for desktops, servers and workstations. Failure to apply the remediation provided below may risk improper authentication validation which could result in disruption of operations and access to system data.

Mitigation summary

Version v1.6 of PowerChute™ Serial Shutdown includes a fix for these vulnerabilities and is available for download here: • Windows: https://www.se.com/ww/en/download/document/SPD-PCSS_WIN_EN/ Reboot needed: Upon installation, the service is automatically restarted. A customer can validate a successful install by checking the version information in the Control Panel or on the About page within PCSS after logging in. Specific instructions and hardening guidelines for these remediations can be found in the [Security Handbook](https://download.se.com/files?p_Doc_Ref=SPD_CCON-PCSSSH_EN).

Revision history (1)
  1. Initial publication — 11 August 2026

    Original Release

Official source: Schneider Electric CPCERT

ICSA-26-204-01

Johnson Controls C-CURE 9000 and Victor application server (Update A)

Johnson Controls Inc. — C-CURE 9000

CISAcritical

Published

23 July 2026

Last update

11 August 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could allow an attacker with network access to achieve remote code execution.

Mitigation summary

Johnson Controls recommends the following upgrades to address the vulnerable deserialization path: Upgrade to C-CURE 9000 v3.20 or later

Revision history (2)
  1. Initial publication — 23 July 2026

    Initial Republication of Johnson Controls Product Security Advisories JCI-PSA-2026-07, JCI-PSA-2026-13, and JCI-PSA-2026-16.

  2. Update A — 11 August 2026

    Update A - Made changes to affected products and mitigations.

Official source: CISA

VDE-2025-007

WAGO: Year 2038 problem

WAGO — CC100

WAGO PSIRTmiddel

Published

15 April 2025

Last update

7 August 2026

Linked CVEs

Affected sectors

Risk evaluation

The Year 2038 Problem affects systems using a 32-bit integer to represent time as the number of seconds since January 1, 1970. On January 19, 2038, at 03:14:07 UTC, the time value will exceed the maximum for a 32-bit integer, causing an overflow and resetting it to a negative number.

Mitigation summary

Update to Firmware 4.10.0 (FW32) or higher. For the latest Custom Firmware, please contact the WAGO support.

Revision history (2)
  1. Initial publication — 15 April 2025

    Initial release.

  2. Update A — 7 August 2026

    Removed G1 devices and changed the fixed firmware to FW32.

Official source: WAGO PSIRT

ICSA-26-218-02

Johnson Controls Inc. TL280

Johnson Controls Inc. — TL280

CISAmiddel

Published

6 August 2026

Last update

6 August 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow an attacker to access sensitive information on the device.

Mitigation summary

To help reduce the risk of exploitation, Johnson Control suggests considering the following defensive measures: Apply firmware update 5.63.

Revision history (1)
  1. Initial publication — 6 August 2026

    Initial Republication of Johnson Controls Security Advisory JCI-PSA-2026-08

Official source: CISA

ICSA-26-218-01

ABB Ability Zenon

ABB — Ability Zenon

CISAhigh

Risk evaluation

ABB is aware of publicly reported vulnerabilities affecting MongoDB 4.2, which is bundled within the IIoT Services of the affected product versions. MongoDB 4.2 has reached end-of-life and contains multiple known security vulnerabilities. An attacker who successfully exploits these vulnerabilities could potentially access sensitive information, cause denial of service, or disrupt system availability.

Mitigation summary

ABB recommends the following mitigation measures: - Replace bundled MongoDB with a supported version if IIoT services are required: - Where IIoT functionality is required, the bundled MongoDB instance can be replaced with a supported and patched version through manual configuration. - The following zenon online help section explains the process of installing and using your own MongoDB database: zenHelpViewer - Uninstall IIoT Services wherever it’s not required: - If IIoT Services are not required, they can be removed using the Control panel uninstaller. This eliminates the dependency on MongoDB without affecting other zenon components. Refer to section “General security recommendations” for further advise on how to keep your system secure.

Revision history (2)
  1. Initial publication — 30 July 2026

    Initial version

  2. Update A — 6 August 2026

    Initial CISA Republication of ABB PSIRT 9AKK108472A9037 advisory

Official source: CISA

PPSA-2026-003

Pilz: Multiple Vulnerabilities affecting industrial PC IndustrialPI

Pilz — IndustrialPI 4

Pilz PSIRThigh

Published

4 August 2026

Last update

4 August 2026

Affected sectors

Risk evaluation

The Linux kernel used in the IndustrialPI, 'linux-image-revpi-v8', prior to version 6.12.91-revpi0-rpi-v8 contains multiple vulnerabilities. Successful exploitation of these vulnerabilities can give an attacker full control over the device.

Mitigation summary

Update kernel package linux-image-revpi-v8 to version 6.12.91-revpi0-rpi-v8 or higher.

Revision history (1)
  1. Initial publication — 4 August 2026

    Initial Version

Official source: Pilz PSIRT

VDE-2026-065

Endress+Hauser: iDTM Debug Interface Vulnerability in the FDI Package Library

Endress+Hauser — FDI Package library

Endress+Hauser PSIRTmiddel

Published

3 August 2026

Last update

3 August 2026

Linked CVEs

Affected sectors

Risk evaluation

A vulnerability in the iDTM FDI allows an attacker with elevated privileges and access to the host system to enable the debug interface by placing a crafted file in the application directory.

Mitigation summary

If an immediate update is not possible, Endress+Hauser recommends the following measures to reduce the risk of exploitation: * Restrict access to affected systems to authorized personnel only * Apply the principle of least privilege and limit administrative access to trusted users. * Protect application installation directories against unauthorized modification through appropriate operating system access controls. Following these recommendations reduces the risk of unauthorized activation.

Revision history (1)
  1. Initial publication — 3 August 2026

    Initial revision

Official source: Endress+Hauser PSIRT

ICSA-26-211-09

Watchfire Controller Software

Watchfire — BC550

CISAmiddel

Published

30 July 2026

Last update

31 July 2026

Linked CVEs

Affected sectors

Risk evaluation

Successful exploitation of this vulnerability could allow a malicious user the ability to deliver malicious firmware that can update and gain full control of the controller.

Mitigation summary

Watchfire has applied the required security patch to all affected controllers under its management. Watchfire recommends users verify their controller software version and upgrade to one of the approved versions below, if they are not already on an approved patch level.

Revision history (2)
  1. Initial publication — 30 July 2026

    Initial Publication

  2. Update A — 31 July 2026

    Updated Product and Remediation details

Official source: CISA

VDE-2026-008

Phoenix Contact: Multiple vulnerabilities in the firmware of CHARX SEC3xxx charging controllers

Phoenix Contact — CHARX SEC

Phoenix Contact PSIRTcritical

Risk evaluation

Multiple vulnerabilities have been identified in the firmware of CHARX SEC-3xxx EV charging controllers, including the CHARX SEC-3000, SEC-3050, SEC-3100, and SEC-3150 models. The flaws could allow attackers to compromise the devices remotely, resulting in a complete loss of confidentiality, integrity, and availability.

Mitigation summary

Phoenix Contact strongly recommends to upgrade to firmware version 1.9.1 which fixes these vulnerabilities.

Revision history (1)
  1. Initial publication — 30 July 2026

    Initial revision.

Official source: Phoenix Contact PSIRT

ICSA-26-211-11

MZ Automation lib60870

MZ Automation GmbH — lib60870

CISAmiddel

Published

30 July 2026

Last update

30 July 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could crash the device being accessed.

Mitigation summary

MZ Automation recommends users update to version 2.4.1 when available.

Revision history (1)
  1. Initial publication — 30 July 2026

    Initial Publication

Official source: CISA

ICSA-26-211-10

MZ Automation GmbH libiec61850

MZ Automation GmbH — libiec61850

CISAhigh

Risk evaluation

Successful exploitation of these vulnerabilities could allow an attacker to cause a denial-of-service condition on the device.

Mitigation summary

MZ Automation GmbH recommends that users update to version 1.6.2.

Revision history (1)
  1. Initial publication — 30 July 2026

    Initial Publication

Official source: CISA

ICSA-26-211-08

o6 Automation open62541

o6 Automation GmbH — open62541 on Windows and Linux

CISAhigh

Published

30 July 2026

Last update

30 July 2026

Affected sectors

Risk evaluation

Successful exploitation of these vulnerabilities could allow an attacker to disclose sensitive information, cause a denial of service, or potentially execute arbitrary code.

Mitigation summary

o6 Automation has prepared mitigations and fixes to address these issues and recommends that users update to the newest version. The new version can be obtained by contacting o6 Automation https://www.o6-automation.com/contact or by downloading from the following locations:

Revision history (1)
  1. Initial publication — 30 July 2026

    Initial Publication

Official source: CISA